Pella 80KM0103 Window User Manual


 
EXTERIOR FINISH
4HEEXTERIORFRAMEANDSASHAREPROTECTEDBYALUMINUMCLADDINGWITHOURTOUGH%NDURA#LAD
®
OR%NDURA#LAD0LUSBAKEDONFACTORY
lNISHTHATNEEDSNOPAINTING#LEANTHISSURFACEWITHMILDSOAPANDWATER3TUBBORNSTAINSANDDEPOSITSMAYBEREMOVEDWITHMINERAL
spirits. DO NOT use abrasives. DO NOT scrape or use tools that might damage the surface.
5SEOFINAPPROPRIATElNISHESSOLVENTSBRICKWASHORCLEANINGCHEMICALSWILLCAUSEADVERSEREACTIONSWITHWINDOWANDDOORMATERIALSAND
voids the Limited Warranty.
CARE AND MAINTENANCE
#AREANDMAINTENANCEINFORMATIONISAVAILABLEINTHE0ELLA/WNERS-ANUAL9OUCANOBTAINANOWNERSMANUALBYCONTACTINGYOURLOCAL
Pella retailer. This information is also available at www.pella.com.
IMPORTANT NOTICE
"ECAUSEALLCONSTRUCTIONMUSTANTICIPATESOMEWATERINlLTRATIONITISIMPORTANTTHATTHEWALLSYSTEMBEDESIGNEDANDCONSTRUCTEDTO
properly manage moisture. Pella Corporation is not responsible for claims or damages caused by anticipated and unanticipated water
INlLTRATIONDElCIENCIESINBUILDINGDESIGNCONSTRUCTIONANDMAINTENANCEFAILURETOINSTALL0ELLAPRODUCTSINACCORDANCEWITH0ELLAS
INSTALLATIONINSTRUCTIONSORTHEUSEOF0ELLAPRODUCTSINWALLSYSTEMSWHICHDONOTALLOWFORPROPERMANAGEMENTOFMOISTUREWITHINTHE
wall systems. The determination of the suitability of all building components, including the use of Pella products, as well as the design
and installation of flashing and sealing systems are the responsibility of the Buyer or User, the architect, contractor, installer, or other
construction professional and are not the responsibility of Pella.
Pella products should not be used in barrier wall systems which do not allow for proper management of moisture within the wall systems,
SUCHASBARRIER%XTERIOR)NSULATIONAND&INISH3YSTEMS%)&3ALSOKNOWNASSYNTHETICSTUCCOOROTHERNONWATERMANAGEDSYSTEMS
%XCEPTINTHESTATESOF#ALIFORNIA.EW-EXICO!RIZONA.EVADA5TAHAND#OLORADOPella makes no warranty of any kind on and
assumes no responsibility for Pella windows and doors installed in barrier wall systems. In the states listed above, the installation
of Pella products in barrier wall or similar systems must be in accordance with Pella’s installation instructions.
0RODUCTMODIlCATIONSTHATARENOTAPPROVEDBY0ELLA#ORPORATIONWILLVOIDTHE,IMITED7ARRANTY
TROUBLESHOOTING - Adjustable Strike Latching Issues
5"#4
"EKVTUBCMFTUSJLFTIJN
TJEFWJFX
4USJLF
GSPOUWJFX
"EK4USJLF4IJN
FOEWJFX
'BDUPSZ
JOTUBMMFE
TJEF
4JEFUPCF
VTFEJO
*TTVF
Issue 2:
Door needs to close more
tightly against the weather-
strip. Remove
THESTRIKEAND
ADJUSTABLESTRIKE
shim. Remove
the tabs from the
ADJUSTABLESTRIKE
shim and install
SOTHATTHETHICKER
side is visible at
THESTRIKEEDGE
2EINSTALLTHESTRIKE
Issue 1:
Door is difficult
to latch. Remove
THESTRIKEAND
ADJUSTABLESTRIKE
shim then reinstall
THESTRIKE
Note: Troubleshooting is for Architect Series
®
and Designer Series
®
only.