Whole House Salt Free Water Softener/Conditioner Tank Installation
1. Level the Pelican Salt Free Water Softener/Conditioner.
Notice:
If the tank is not level, lift the tank straight up 6 inches and tap it on the ground until the tank stands
vertical. The bottom of the tank is round and the boot allows the tank to stand upright.
Figure 8
2. Determine the size and material of your incoming water supply line from the Whole House Water
Filter and choose the appropriate fittings required to connect it to the Bypass Valve.
CAUTION:
Do not over-tighten any of the fittings during installation.
Table 3: Bypass Valve Fittings
Note: The fitting below is designed with a ¼
" give to allow for proper pipe alignment. It will not leak and
is intended to have some flexibility.
3. Install the fitting onto the upflow and downflow inlet sides of the Bypass Valve. Follow the
diagrams supplied with the fitting.
4. Connect the incoming water supply from the Pre-Filter System to the fitting on the upflow inlet
side of the Bypass Valve.
5. Connect the outgoing water supply to the downflow inlet side of the Bypass Valve.
Part Description Qty.
1" Plastic Male NPT Assembly:
V3007-04 WS1 Fitting 1" Plastic Male
NPT Assembly (2): O-Rings (2), Split
Rings (2), and Connectors (2)
1
bag
IN
OUT
PVC Fitting*
1" NPT Assembly
Outgoing
Water
To House
Incoming
Water
Supply
Wall Wall
Whole House
Water Filter
Pre-Filter
Salt Free Water
Softener/Conditioner
*Customer supplied,
choose appropriate