Pelco Spectra IV SE Home Security System User Manual


 
C3417M-B (11/06) 5
6. Suspended Ceiling Only: Install the ceiling tile with the back box. Attach a T-rail clip on each side of the ceiling
tile.
7. Connect wiring to the circuit board inside the back box. When finished, close the door to the back box and turn on the
power. The green LED will light.
NOTES:
Aux 1: Maximum 2 A at low voltage (<40 V)
Aux 2: Maximum 30 mA at 32 VDC
If you are using both unshielded twisted pair (UTP) wiring and a translator board, install the UTP wiring before
installing the translator board.
If you are installing an environmental back box in a railway application, attach a ground wire from the circuit
board power connector to a structural ground using at least 18-gauge wire.
WARNING: An electrical short in the back box may occur if the metal BNC connector is not completely covered by
the protective boot.