Pelco Spectra IV SE Home Security System User Manual


 
14 C3417M-B (11/06)
Specifications
The materials used in the manufacture of this document and its components are compliant to the requirements of Directive 2002/95/EC.
This equipment contains electrical or electronic components that must be recycled properly to comply with Directive 2002/96/EC of the
European Union regarding the disposal of waste electrical and electronic equipment (WEEE). Contact your local dealer for procedures
for recycling this equipment.
4.3
(10.9)
9.9 (25.2)
4.4
(11.0)
5.9 (15.0)
8.9 (22.6)
7.5 (19.0)
5.2
(13.2)
8.2 (20.8)
3.5
(8.8)
5.9 (15.0)
NOTE: VALUES IN PARENTHESES ARE CENTIMETERS;
ALL OTHERS ARE INCHES.
*For variable-speed operation an appropriate controller is
required. With fixed-speed controllers, pan/tilt speed is 20°/sec.
The CM6700/CM6800 controller with the KBD200A keyboard has
programmable fixed speeds.
GENERAL
Construction
Back Box Plastic
Dome Drive Aluminum, thermoplastic
Lower Dome Acrylic
Cable Entry (Back Box) 0.75-inch conduit fitting
Pan Movement 360° continuous pan rotation
Vertical Tilt Unobstructed +2° to -92°
Manual Pan/Tilt Speeds*
Pan 0.1°- 80°/sec manual operation,
150°/sec turbo
Tilt 0.1°- 40°/sec manual operation
Preset Speeds
Pan 400°/sec
Tilt 200°/sec
Environment
In-Ceiling Indoor
Environmental In-Ceiling Outdoor
Operating Temperature
In-Ceiling Indoor 32° to 122°F (0° to 50°C)
Environmental In-Ceiling (Assumes no wind chill factor)
Maximum 140°F (60°C) absolute maximum;
122°F (50°C) sustained maximum
Minimum -60°F (-51.1°C) absolute minimum;
prevents icing at sustained
minimum of -50°F (-45°C); de-ices
0.1 inch (2.5 mm) within 3 hours
after power-up
Weight (approximate)
Back Box
In-Ceiling Indoor 1.5 lb (0.68 kg)
Environmental In-Ceiling 2.1 lb (0.95 kg)
Dome Drive 3.3 lb (1.48 kg)
Lower Dome
In-Ceiling Indoor 0.2 lb (0.09 kg)
Environmental In-Ceiling 0.6 lb (0.27 kg)
ELECTRICAL (Dome Drive Only)
Input Voltage 18-32 VAC; 24 VAC nominal
22-27 VDC; 24 VDC nominal
Input Power
24 VAC 23 VA nominal (indoor, without heater)
73 VA nominal (outdoor, with heater)
24 VDC 0.7 A nominal (indoor, without heater)
3 A nominal (outdoor, without heater)
Fuse 1.25 A
Auxiliary Outputs 2 (Spectra IV SE only)
Alarm Inputs 7 (Spectra IV SE only)
Relay Contacts AUX 1
AUX 2 Output
Type Form C Open collector
transistor output
Voltage Low voltage (<40 V) 32 VDC maximum
Current 2 A maximum 150 mA maximum
Environmental In-Ceiling In-Ceiling