APPLICATIONS
Figures 4-7 show how to use the transceivers in various applications. The terminal block on the back
of the TW3004P has tension clamps instead of screw terminals.
To connect the UTP wires to the terminal block:
1. Use a small screwdriver to open the clamps (+ and -) for each channel.
2. Insert each wire into the appropriate holes. Figure 3 shows the UTP wires for channel 1.
Figure 3.
Terminal Block UTP Connections
Table A shows the distance in feet with coaxitron or video only when using a particular type of
Cat cable. Table B shows the maximum allowable wire gauge for single wire and stranded wire.
NOTE:
Cat5e cable is recommended for optimum video performance.
Table A.
Cable Distance
Cable Type
Distance
(with Coaxitron)
Distance
(video only)
Cat3 300 ft 400 ft
Cat5 500 ft 650 ft
Cat5e 750 ft 750 ft
Cat6 750 ft 750 ft
Table B.
Wire Gauge
Wire Gauge (maximum allowable)
Single Wire (solid)
24 AWG (1.5 mm
2
)
Stranded Wire (flexible)
24 AWG (1.0 mm
2
)