Panasonic HQ-2102UH Air Conditioner User Manual


 
1 Air inlet louver 4 Air filter (behind the
front intake grille)
2 Cabinet 5 Front intake
grille
3 Power cord 6 Front grille
7 Vertical airflow direction vane
(Airflow direction adjustment up-
down).
The vertical airflow direction vane
is controlled by rotating the
horizontal vane forward or backward.
2
AIR CONDITIONER INSTALLATION
3
PART IDENTIFICATION
REMOVAL OF FRONT GRILLE
1 Remove the front intake grille.
Pull up the front intake
grille about 90° and slide
it slightly to the left to
unhook the tabs.
2 Remove the air filter.
Tilt up and pull
out the air filter
by the holder.
3 Remove the front grille.
At bottom right side of the front grille, press inward on cabinet near the power cord, and pull
the grille outward to the right until right tab releases.
At the bottom left side, push inward on cabinet and pull the grille outward to the left to release
the left tab.
Do not pull the bottom edge toward you more than 3 inches to prevent the two top tabs from
damage.
Slide the front grille upwards to free the two top tabs from slots at the top of the cabinet.
HOW TO ATTACH THE DRAIN PAN (OPTIONAL)
Maximum
13/32
Condensed water
This air conditioner employs a Slinger-Up System which is designed to splash the condensed
water on the condenser coil for maximum cooling efficiency, thus producing a splashing sound.
If the splashing sound annoys you, you can provide an outside drainage by using the following
procedure which may, however, cause a small loss of performance.
Note: The cabinet should be installed tilted slightly lower to the rear for necessary condensate
drainage. (Max. 13/32)
Condensed water drainage
1 Remove the rubber plug and slide the chassis out from
the cabinet.
Remove the
rubber plug