Panasonic EQ-500 Series Smoke Alarm User Manual


 
201
EQ-500
PRECAUTIONS FOR PROPER USE
Part description
Multi-voltage type (L-ON / D-ON mode only)
DC-voltage type
Description
Operation mode switch
Detection-ON mode is obtained when the switch
is turned fully clockwise (L side).
Detection-OFF mode is obtained when the switch
is turned fully counterclockwise (D side).
Operation mode switch
L-ON
D-ON
L-ON
BGS
FGS
D-ON
BGS / FGS function (DC-voltage type only)
DC-voltage type sensor incorporates BGS / FGS function. Select
either the BGS or FGS function depending on the positions of the
background and sensing object.
BGS / FGS function is set with the operation mode switch.
Depends on a selection of either BGS or FGS function, the out-
put operation changes as follows.
ON
OFF
ON
OFF
ON
OFF
ON
OFF
Setting distance
Non-detectable area
Detectable range
Screw for terminal cover fixing
Screwdriver
The tightening torque for the terminal screws should be 0.3 to 0.5 Nm.
Round type Y-shaped type
The size of conduit is M20
ן1.5.
If pressure terminals are to be used, affix the connected
pressure terminals to a terminal (M3.5 screw).
Dimensions of the suitable crimp terminals
(Unit: mm in)
(After crimping)
7.5 0.295
or less
22 0.866
or less
17 0.669
or less
7 0.276
or less
10 0.394
or less
"3.6
"0.142
or more
(After crimping)
7.5 0.295
or less
22 0.866
or less
17 0.669
or less
7 0.276
or less
10 0.394
or less
3.6 0.142
or more
Make sure that the power supply is off while wiring.
Check all wiring before applying power since incorrect wiring may
damage the internal circuit. Also, carefully tighten the terminal
screws so that the wires of adjacent terminals do not touch.
The mounting hole for the terminal cover fixing screws inclines
70 degrees to the terminal cover, as shown in the figure below.
To avoid damaging this product or screw, take care when
tightening or loosening a screw.
To maintain water-resistance, the cable should have an outer
diameter between "9 to "11 mm "0.354 to "0.433 in with a
smooth covering material that allows the attached conduit
connector to be securely tightened; the tightening torque of the
screw should be of 1.5 to 2.0 Nm.
Verify that the supply voltage variation is within the rating.
If power is supplied from a commercial switching regulator,
ensure that the frame ground (F.G.) terminal of the power supply
is connected to an actual ground.
In case noise generating equipment (switching regulator, inverter
motor, etc.) is used in the vicinity of this sensor, connect the
frame ground (F.G.) terminal of the equipment to an actual ground.
Do not run the wires together with high-voltage lines or power
lines or put them in the same raceway. This can cause
malfunction due to induction.
If an external surge voltage exceeding 4 kV is impressed (DC-
voltage type: 1 kV), the internal circuit will be damaged, and a
surge suppressing element should be used.
Prepare the cable end as shown below.
Conduit connector construction and cabling
Gland packing (Note)
Gland
Power supply
Conduit connector
Output
37 mm
1.457 in
25 mm
0.984 in
Wiring
When assembling the conduit connector, pay attention to the direction
of the gland packing.
Furthermore, in order to maintain water-resistance, fit the gland
packing such that the seating surface of the gland packing contacts
the packing holder part of the terminal cover evenly.
Note:
Note:
Use crimp terminals with insulating sleeves.
Recommended crimp terminal: Nominal size 1.25ן3.5 0.049ן0.138.
Distance adjuster (2-turn)
Adjuster indicator
Stability indicator (Green)
Operation indicator (Orange)
OFF-delay timer adjuster (Note 2)
ON-delay timer adjuster (Note 2)
Operation mode switch (Note 1)
Notes: 1)
2)
The operation mode switch of the DC-voltage type is the DIP
switch. Refer to ‘DC-voltage type’ of ‘Operation mode switch
for details.
Incorporated on EQ-5T only.
Note: Turn the operation mode switch gradually and lightly with the attached
screwdriver. Turning with excessive strength will cause damage to the
adjuster.
LD
BGS FGS
Timer ONOFF
N.C.N.C.
L-ON / D-ON mode
BGS / FGS mode
Timer mode
Not used
08/2005