Panasonic CW-XC85HU Air Conditioner User Manual


 
14
Features and Installation
Use Wall Receptacle Power Supply
Standard 125V, 3-wire grounding
receptacle rated 15A, 125V AC
Use 15 AMP. time
delay fuse or 15 AMP.
circuit breaker.
Electrical Data
USE OF EXTENSION CORDS
Because of potential safety hazards, we strongly discourage the use of an extension cord. However, if you wish to
use an extension cord, use a CSA certified/UL-listed 3-wire (grounding) extension cord, rated 15A, 125V.
All wiring should be made in accordance with local electrical codes and regulations.
NOTE :
Aluminum house wiring may pose special problems. Consult a qualified electrician.
ELECTRICAL SAFETY
IMPORTANT GROUNDING INSTRUCTIONS
Air conditioner has a three-prong grounding plug on its power supply cord, which must be plugged into
properly grounded three-prong wall receptacle for your protection against possible shock hazard.
Power cord may include a current interrupter device. A test and reset button is provided on the plug
case. The device should be tested on a periodic basis by first pressing the TEST button and then the
RESET button. If the TEST button does not trip or if the RESET button will not stay engaged,
discontinue use of the air conditioner and contact a qualified service technician.
Damaged power supply cord must be replaced with a new power supply cord obtained from the product
manufacture and not repaired.