Panasonic CU-TE9DKE Air Conditioner User Manual


 
14.2. Sensible Capacity Chart
CS-TE9DKE / CU-TE9DKE
230V Outdoor Temp. (°C)
Indoor wet
bulb temp.
30 35 40 46
TC SHC IP TC SHC IP TC SHC IP TC SHC IP
17.0°C 2.58 2.33 0.53 2.41 2.24 0.57 2.24 2.14 0.61 2.04 2.03 0.66
19.0°C 2.60 0.58
19.5°C 2.83 2.44 0.54 2.65 2.34 0.58 2.46 2.25 0.62 2.24 2.14 0.67
22.0°C 3.09 2.52 0.56 2.88 2.43 0.60 2.68 2.34 0.64 2.44 2.24 0.69
CS-TE12DKE / CU-TE12DKE
230V Outdoor Temp. (°C)
Indoor wet
bulb temp.
30 35 40 46
TC SHC IP TC SHC IP TC SHC IP TC SHC IP
17.0°C 3.42 2.86 0.82 3.20 2.75 0.89 2.97 2.64 0.95 2.70 2.51 1.02
19.0°C 3.45 0.95
19.5°C 3.76 3.01 0.84 3.51 2.89 0.90 3.27 2.78 0.97 2.97 2.64 1.04
22.0°C 4.10 3.12 0.85 3.83 3.06 0.92 3.56 2.89 0.99 3.24 2.75 1.06
76
CS-TE9DKE CU-TE9DKE / CS-TE12DKE CU-TE12DKE