Panasonic CS-E18GFEW-2 Air Conditioner User Manual


 
35
9.2. Sensible Capacity Chart
O CS-E9GFEW-2 CU-E9GFE-2
O CS-E12GFEW-2 CU-E12GFE-2
O CS-E18GFEW-2 CU-E18GFE-2
220V Outdoor Temp. (°C)
230V 30°C35°C40°C46°C
240V TC SHC IP TC SHC IP TC SHC IP TC SHC IP
D.B. W.B. kW kW kW kW kW kW kW kW kW kW kW kW
27
17.0 2.48 2.13 0.52 2.32 2.05 0.56 2.16 1.97 0.60 1.96 1.88 0.65
19.0 2.50 0.57
19.5 2.72 2.23 0.53 2.55 2.15 0.57 2.37 2.06 0.61 2.15 1.97 0.66
22.0 2.96 2.31 0.54 2.77 2.22 0.58 2.58 2.13 0.62 2.34 2.03 0.67
220V Outdoor Temp. (°C)
230V 30°C35°C40°C46°C
240V TC SHC IP TC SHC IP TC SHC IP TC SHC IP
D.B. W.B. kW kW kW kW kW kW kW kW kW kW kW kW
27
17.0 3.47 2.49 0.89 3.25 2.40 0.96 3.02 2.30 1.03 2.74 2.20 1.11
19.0 3.50 0.97
19.5 3.81 2.61 0.90 3.57 2.51 0.97 3.32 2.41 1.04 3.02 2.30 1.12
22.0 4.15 2.70 0.92 3.88 2.60 0.98 3.61 2.49 1.06 3.28 2.38 1.14
220V Outdoor Temp. (°C)
230V 30°C35°C40°C46°C
240V TC SHC IP TC SHC IP TC SHC IP TC SHC IP
D.B. W.B. kW kW kW kW kW kW kW kW kW kW kW kW
27
17.0 4.96 3.26 1.44 4.64 3.14 1.54 4.32 3.01 1.65 3.92 2.87 1.78
19.0 5.00 1.56
19.5 5.45 3.41 1.45 5.10 3.28 1.56 4.74 3.15 1.67 4.31 3.01 1.80
22.0 5.92 3.53 1.47 5.55 3.40 1.58 5.16 3.26 1.70 4.69 3.11 1.83
TC
SHC
IP
-
-
-
Total Cooling Capacity (kW)
Sensible Heat Capacity (kW)
Input Power (kW)
Indoor 27°C/19°C
Outdoor 35°C/24°C