Panasonic CS-E12GFEW-2 Air Conditioner User Manual


 
9
1. Cooling capacities are based on indoor temperature of 27°C Dry Bulb (80.6°F Dry Bulb), 19.0°C Wet Bulb (66.2°F Wet Bulb)
and outdoor air temperature of 35°C Dry Bulb (95°F Dry Bulb), 24°C Wet Bulb (75.2°F Wet Bulb)
2. Heating capacities are based on indoor temperature of 20°C Dry Bulb (68°F Dry Bulb) and outdoor air temperature of 7°C Dry
Bulb (44.6°F Dry Bulb), 6°C Wet Bulb (42.8°F Wet Bulb)
Note
Specifications are subject to change without notice for further improvement.
Fan
Type Turbo Fan Propeller Fan
Material ASG PP
Motor Type Transistor (8-pole) Transistor (8-pole)
Input Power W 62.1
Output Power W 48 40
Fan Speed
QLo (Cool/Heat) rpm 490 / 490
Lo (Cool/Heat) rpm 570 / 610
Me (Cool/Heat) rpm 660 / 740
Hi (Cool/Heat) rpm 760 / 870 660 / -
SHi (Cool/Heat) rpm 800 / 910
Heat Exchanger
Fin Material Aluminium (Pre Coat) Aluminium (Pre Coat)
Fin Type Slit Fin Corrugated Fin
Row x Stage x FPI 2 x 22 x 19 2 x 34 x 16
Size (W x H x L) mm 510 x 396 x 24
36.4 x 714 x 803.2
831.9
Air Filter
Material PET
Type Honeycomb
Item Unit
Power Source (Phase, Voltage, Cycle)
ø Single
V 220 - 240
Hz 50
Input Power W
Cooling; 1550 (255 ~ 1910)
Heating; 1600 (260 ~ 2350)
Starting Current A 7.35
Running Current A
Cooling; 7.20 - 6.90
Heating; 7.35 - 6.95
Maximum current A 10.5
Power Factor %
Cooling; 98 - 94
Heating; 99 - 96
Power factor means total figure of compressor, indoor fan motor and outdoor fan motor.
Power Cord
Number of core
Length m
Thermostat Electronic Control
Protection Device Electronic Control
ITEM UNIT INDOOR UNIT OUTDOOR UNIT