Panasonic CS-E12GFEW-2 Air Conditioner User Manual


 
5
1. Cooling capacities are based on indoor temperature of 27°C Dry Bulb (80.6°F Dry Bulb), 19.0°C Wet Bulb (66.2°F Wet Bulb)
and outdoor air temperature of 35°C Dry Bulb (95°F Dry Bulb), 24°C Wet Bulb (75.2°F Wet Bulb)
2. Heating capacities are based on indoor temperature of 20°C Dry Bulb (68°F Dry Bulb) and outdoor air temperature of 7°C Dry
Bulb (44.6°F Dry Bulb), 6°C Wet Bulb (42.8°F Wet Bulb)
Note
Specifications are subject to change without notice for further improvement.
Fan
Type Turbo Fan Propeller Fan
Material ASG PP
Motor Type Transistor (8-pole) Induction (6-pole)
Input Power W 66.0 - 74.1
Output Power W 48 25
Fan Speed
QLo (Cool/Heat) rpm 360 / 360
Lo (Cool/Heat) rpm 410 / 410
Me (Cool/Heat) rpm 510 / 520
Hi (Cool/Heat) rpm 620 / 630 745 - 790 / -
SHi (Cool/Heat) rpm 660 / 670
Heat Exchanger
Fin Material Aluminium (Pre Coat) Aluminium (Pre Coat)
Fin Type Slit Fin Corrugated Fin
Row x Stage x FPI 2 x 22 x 19 2 x 24 x 17
Size (W x H x L) mm 510 x 396 x 24
36.4 x 504 x 713
684
Air Filter
Material PET
Type Honeycomb
Item Unit
Power Source (Phase, Voltage, Cycle)
ø Single
V 220 - 240
Hz 50
Input Power W
Cooling; 570 (175 ~ 780)
Heating; 865 (165 ~ 1360)
Starting Current A 4.20
Running Current A
Cooling; 2.75 - 2.65
Heating; 4.20 - 3.90
Maximum current A 6.15
Power Factor %
Cooling; 94 - 90
Heating; 94 - 92
Power factor means total figure of compressor, indoor fan motor and outdoor fan motor.
Power Cord
Number of core
Length m
Thermostat Electronic Control
Protection Device Electronic Control
ITEM UNIT INDOOR UNIT OUTDOOR UNIT