Panasonic CS-E12CKP Air Conditioner User Manual


 
8
ENGLISH
Pre-season Inspection
Is the discharged air cold/warm?
Operation is normal if 15 minutes after the start of
operation, the difference between the air intake and
outlet vents temperature is:-
Are the air intake or outlet vents of the indoor or
outdoor units obstructed?
Are the remote control batteries weak?
If the remote control display appears weak, replace
the batteries.
When the Air Conditioner is Not Used
for an Extended Period of Time
1 To dry the internal parts of the indoor unit, operate
the unit for 2 - 3 hours using:-
2 Turn off the power supply and unplug.
Note: If the unit is not switched off by the remote
control, it will start operating when you plug in
(because the unit is equipped with Auto Restart
Control).
3 Remove the remote control batteries.
Recommended Inspection
After used over several seasons, the unit will
become dirty and thus decreases the units
performance. Depending on the operation
conditions, a dirty unit may produce odour and dust
may pollute dehumidification system. Therefore, a
seasonal inspection is recommended in addition to
regular cleaning. (Consult an authorized dealer).
CARE AND MAINTENANCE
Cleaning the Indoor Unit and Remote
Control
Wipe gently with a soft, dry cloth.
Do not use water hotter than 40˚C or polishing fluid
to clean the unit.
Cleaning the Air Filter
(Recommendation:- If the unit is operated in a dusty
environment, clean the filters every two weeks,
continuous use of this dirty filters will reduce cooling
or heating efficiency)
1 Remove dirt using a vacuum cleaner.
2 Wash back of the air filter with water.
3 If badly soiled, wash it with soap or a mild household
detergent.
4 Let it dry and reinstall it.
Be sure the FRONT mark is facing you.
* Damaged air filter.
Consult the nearest authorized dealer.
Part No.: CWD001047.
Do not use benzene, thinner, scouring powder or
clothes soaked in caustic chemical to clean the unit.
Cleaning the Front Panel
(Must be removed before washing)
1 Raise the front panel higher than the horizontal and
pull to remove it.
2 Gently wash with water and a sponge.
Do not press the front panel too hard when washing.
When use kitchen cleaning fluid (neutral detergent),
rinse throughly.
Do not dry the front panel under direct sunlight.
3 To fix the front panel, raise the front panel
horizontally, match the protruding portion on the
indoor unit to the fulcrum and push into place.
Air Purifying Filters
Triple Deodorizing Filter
Absorb odours produced by wall paper, construction
material and living environment.
Reusable.
Vacuum, place under direct sunlight for 6 hours and
fit it back in place.
(Recommended : every 6 months)
Catechin Air Purifying Filter
The filter is coated with catechin to prevent growth
of bacteria and viruses.
Reusable.
Vacuum and fit it back in place
(Recommended : every 6 months)
Recommended to change these filters every 3 years.
Do not reuse damaged filters.
Consult the nearest authorized dealer to purchase a
new filter.
Catechin Air Purifying Filter No.: CZ-SF70P
Triple Deodorizing Filter No.: CZ-SFD72P
If you operate the air conditioner with dirty filters:-
Air is not purified
Cooling capacity decreases
Foul odour is emitted
FAN operation
Fulcrum
Protruding portion on indoor unit
2
Remove the air filters
1
Raise the
front panel
Catechin Air
Purifying Filter
Triple Deodorizing
Filter
COOL 8°C or above
HEAT 14°C or above