5
2 Specifications
MODEL
INDOOR CS-CE9JKE
OUTDOOR CU-CE9JKE
Performance Test Condition EUROVENT
Power Supply
Phase, Hz Single, 50
V 230
Min. Mid. Max.
Cooling
Capacity
kW 0.60 2.60 3.00
BTU/h — — —
Kcal/h 520 2240 2580
Running Current A — 2.8 —
Input Power W 125 590 750
Annual Consumption kWh — 295 —
EER
W/W 4.80 4.41 4.00
Kcal/hW 4.16 3.80 3.44
Power Factor % — 92 —
Indoor Noise (H / L)
dB-A 39 / 25
Power Level dB 55 / 42
Outdoor Noise (H / L)
dB-A 46 / -
Power Level dB 61 / -
Heating
Capacity
kW 0.60 3.60 5.00
BTU/h — — —
Kcal/h 520 3100 4300
Running Current A — 3.9 —
Input Power W 120 835 1.34k
COP
W/W 5.00 4.31 3.73
Kcal/hW 4.33 3.71 3.21
Power Factor % — 93 —
Indoor Noise (H / L)
dB-A 40 / 27
Power Level dB 56 / 43
Outdoor Noise (H / L)
dB-A 47 / -
Power Level dB 62 / -
Low Temp. : Capacity (kW) / I.Power (W) / COP 3.62 / 1.19k / 3.04
Extr Low Temp. : Capacity (kW) / I.Power (W) / COP 3.05 / 1.27k / 2.40
Max Current (A) / Max Input Power (W) 6.0 / 1.34k
Starting Current (A) 3.9
Compressor
Type Hermetic Motor
Motor Type Brushless (4-poles)
Output Power W 750
Indoor Fan
Type Cross-flow Fan
Material ASG20K1
Motor Type Transistor (8-poles)
Input Power W 47
Output Power W 40
Speed
Lo
Cool/Fan rpm 750
Heat rpm 800
Me
Cool/Fan rpm 935
Heat rpm 1015
Hi
Cool/Fan rpm 1120
Heat rpm 1230