Panasonic CS-CE9JKE Air Conditioner User Manual


 
33
12.4.2. Horizontal Airflow
The horizontal airflow direction louvers can be adjusted manually by hand.
12.5. Timer Control
12.5.1. ON Timer Control
• ON timer can be set using remote control, the unit with timer set will start operate earlier than the setting time. This is to provide
a comfortable environment when reaching the set ON time.
60 minutes before the set time, indoor (at fan speed of Lo-) and outdoor fan motor start operate for 30 seconds to determine the
indoor intake air temperature and outdoor air temperature in order to judge the operation starting time.
From the above judgment, the decided operation will start operate earlier than the set time as shown below.
12.5.2. OFF Timer Control
OFF timer can be set using remote control, the unit with timer set will stop operate at set time.
12.6. Auto Restart Control
1. When the power supply is cut off during the operation of air conditioner, the compressor will re-operate within three to four
minutes (there are 10 patterns between 2 minutes 58 seconds and 3 minutes 52 seconds to be selected randomly) after
power supply resumes.
2. This type of control is not applicable during ON/OFF Timer setting.
12.7. Indication Panel
Note:
• If POWER LED is blinking, the possible operation of the unit are Hot Start, during Deice operation, operation mode judgment, or
ON timer sampling.
If Timer LED is blinking, there is an abnormality operation occurs.
LED POWER TIMER
Color Green Orange
Light ON Operation ON Timer Setting ON
Light OFF Operation OFF Timer Setting OFF