Panasonic CS-C9DKU Air Conditioner User Manual


 
During Anti-Dew condensation prevention, Airflow Direction Manual Control angle change from 10°, 15°, 20°, 26°, 32° to
22°, 24°, 26°, 28°, 30°.
8.5. Indoor Fan Speed Control
Indoor Fan Speed can be set using remote control.
8.5.1. Fan Speed Rotation Chart
Speed Fan Speed (rpm)
CS-C9DKU CS-C12DKU
SHi 1250 1310
Hi 1160 1280
Me 920 1080
HLo 840 960
CLo 750 900
Lo- 750 850
SLo 710 820
SS Lo - -
QSHi - -
QHi 1060 1180
QMe 820 980
QH Lo - -
QLo 650 800
21
CS-C9DKU CU-C9DKU / CS-C12DKU CU-C12DKU