Panasonic CS-C9DKU Air Conditioner User Manual


 
CS-C9DKU CU-C9DKU
CS-C12DKU CU-C12DKU
REMARKS
B : BLUE
BR : BROWN
BL : BLACK
GRY : GRAY
O : ORANGE
P : PINK
R : RED
W : WHITE
Y/G : YELLOW/GREEN
Power Supply Cord
Resistance of Indoor Fan Motor Windings
MODEL CS-C9DKU
CS-C12DKU
CONNECTION CWA921143
BLUE-YELLOW 82.4
YELLOW-RED 103.4
Note: Resistance at 68°F of ambient temperature.
Resistance of Outdoor Fan Motor Windings
MODEL CU-C9DKU
CU-C12DKU
CONNECTION CWA951244
BLUE-YELLOW 61.2
YELLOW-RED 53.4
Note: Resistance at 78.8°F of ambient temperature.
Resistance of Compressor Windings
MODEL CU-C9DKU CU-C12DKU
CONNECTION 2R135126A 2P19S126C-1A
C-R 0.938 0.613
C-S 2.611 2.106
Note: Resistance at 77°F/68°F of ambient temperature.
7 Wiring Diagram
14
CS-C9DKU CU-C9DKU / CS-C12DKU CU-C12DKU