Panasonic CS-A12CTP Air Conditioner User Manual


 
NAME OF EACH PART
Remote Control
Remote Control Signal.
Make sure it is not obstructed.
Maximum distance : 10 m.
Signal received sound.
One short beep or one long beep.
Notes for Remote Control.
Do not throw or drop.
Do not get it wet.
Certain type of fluorescent lamps may affect
signal reception. Consult your dealer.
Do not place the remote control in a location exposed
to direct sunlight, or next to a heating unit, or other
heat source.
How to Insert the Batteries
1
Gently press the place marked OPEN and slide
the cover towards you.
2
Insert the batteries
Be sure the direction is correct.
About the batteries
Can be used for approximately one year.
Observe the following when replacing the batteries
Replace with new batteries of the same type.
Do not use rechargeable batteries (Ni-Cd).
Remove the batteries if the unit is not going to be
used for a long period.
Proper way to operate the remote control in the
case of ceiling/wall mounting.
Operate the remote control in parallel with the floor.
(See the figure below)
1 Signal Transmitter
2 Operation Display
3 Room Temperature Setting Button
(Illuminating button)
4 Operation Mode Selection Button
5 Sleep Mode Operation Button
(Illuminating button)
6 Timer Setting Button
7 Timer Selection Button
8 OFF/ON Button
(Illuminating button)
9 Fan Speed Selection Button
0 Auto Airflow Direction Button
! Timer Set/Cancel Button
@ Manual Airflow Direction Selection Button
# Reset Point
(Press with fine-tipped object to clear the memory)
Cooling Model
Heat Pump Model
HH
The signal changes as shown in the figure below.
It means that the receiving conditions are bad and
the signal can not be controlled properly.
O.K.
OUT
(Fig. 2)
(Fig. 1) Horizontal Level
HOW TO OPERATE
To start the operation
Press 1.
POWER indicator (green) on the indoor unit will light up.
To stop, press once more.
Setting Mode
Press 2 to select:-
Cooling Model
AUTO Automatic Operation
COOL Cooling Operation
DRY Soft Dry Operation
FAN Air Circulation Operation
Heat Pump Model
AUTO Automatic Operation
HEAT Heating Operation
COOL Cooling Operation
DRY Soft Dry Operation
PREPARATION BEFORE OPERATION
Indoor Unit
1
Connect the power supply cord to an independent
power supply.
Setting Temperature
Press 3 to increase or decrease the temperature.
The temperature can be set between 16°C ~ 30°C
Recommended temperature:
During AUTO Operation, press 3 to select:-
Operation with 2°C higher than the standard
temperature.
Operation with the standard temperature.
Operation with 2°C lower than the standard
temperature.
Standard Temperature
Cooling Model
Once the Automatic Operation is selected, the indoor
temperature sensor operates automatically to select
the desired operation mode with Cooling or Soft Dry.
After the operation mode has been selected, the
mode does not change.
Heat Pump Model
At the beginning of the automatic operation, Heating,
Cooling or Soft Dry is automatically selected according
to the indoor temperature.
After the operation mode has been selected, the
mode does not change.
Operation
Cooling
Soft Dry
Standard
temperature
25°C
22°C
Indoor
temperature
23°C
Operation
Cooling
Soft Dry
Heating
Standard
temperature
25°C
22°C
21°C
Indoor
temperature
23°C
20°C
Cooling Model
COOL > 26°C ~ 28°C
DRY > 1°C ~ 2°C
lower than the
room temperature
Heat Pump Model
COOL > 26°C ~ 28°C
DRY > 1°C ~ 2°C
lower than the
room temperature
HEAT >20°C ~ 24°C
Operation Details
COOL Cooling Operation
To set the room temperature at your preference
cooling comfort.
AUTO Automatic Operation
Sense indoor temperature to select the optimum
mode.
Temperature is not displayed on the remote control
during AUTO operation.
DRY Soft Dry Operation
A very gentle Cooling Operation, prior to
dehumidification. It does not lower the room
temperature.
During Soft Dry operation, the indoor fan operates at
Low Fan Speed.
HEAT Heating Operation
(for Heat Pump Model only)
Heat is obtained from outdoor air to warm up the
room. When the outdoor ambient air temperature
falls, the heating capacity of the unit might be
reduced.
Defrosting Operation
Depend on the outdoor temperature, the operation
occasionally stops to melt the frost on the outdoor
unit.
FAN Air Circulation Operation
(for Cooling Model only)
Heated air rises and collects at the top of the room.
The air circulation circulates the heated air downward,
thus increasing heating effectiveness. When the unit
is installed floor mounted, you should set the
temperature higher than that of ceiling mounted.
At ceiling mounted At floor mounted
1
36
CS-A12CTP CU-A12CTP5 / CS-A18CTP CU-A18CTP5 / CS-A24CTP CU-A24CTP5