Oreck USER'S GUIDE Vacuum Cleaner User Manual


 
6
Refilling Your Canister Vapor Cleaner With Water
Step 1: Press On/Off Button to turn the unit “Off”. Depress the Vapor Switch only
on the Pistol Grip to “On” and leave “On” for 10 minutes to ensure that
any remaining pressure in the boiler has been released.
Step 2: Depress the Vapor Switch on the Pistol Grip to the “Off” position and
disconnect Electrical Power Cord from wall outlet.
Step 3: Wait an additional 10 minutes before opening the Safety Cap. Carefully
loosen the Safety/Filler Cap by rotating counterclockwise. Any residual
steam will be released below the Safety/Filler Cap if the tank has not
been completely vented. When the hissing stops and the last of the
vapor has been released, remove the filler cap.
Step 4: Allow the vapor cleaner to cool for 5-10 minutes before refilling with
water.
Step 5: Refill water tank with water using the Refill Bottle, as previously described.
Step 6: Firmly screw the Safety Filler Cap back onto the Vapor Cleaner by
turning clockwise and pressing down lightly.
Step 7: Connect power cord to the wall outlet. Press the On/Off Power Switch
and wait until the Temperature Ready Light comes on before you
continue cleaning.
WARNING: If you attempt to refill the machine while the Vapor
Generator is still hot, there is a risk that water will be squirted back
during filling and cause scalding. Extreme care should be taken
when refilling the unit.
Using Your Canister Vapor Cleaner with Floor Brush
Step 1: Connect one of the Extension
Tubes to the Pistol Grip on the
Flexible Vapor Hose. To insert
the Extension Tubes one onto
the other or onto the Pistol Grip,
press the button ensuring that it
fits into the hole. To disconnect,
repeat the operation by pressing
the button and pulling the two
pieces apart.