Lifebreath 195DCS Air Cleaner User Manual


 
35
FAN MOTOR
GRN
T12
T13
CAPACITOR
WHITE
BLK
BRO
WN
BROWN
DIRECT MOUNTED CAPACITOR
T9
T10
T11
T12
T13
T14
T5
T4
T3
GROUND
DOOR SWITCH
WHITE
BLACK
HIGH VOLTAGE
12V LOW VOLTAGE
FIELD INSTALLED
LEGEND
12V LOW VOLTAGE
GRN
Note:
If any of the original
wire as supplied with
the unit must be replaced,
use only TEW certified wire
P3
AUTO-
TRANS
FORMER
120V
POWER SUPPLY
CORD
FAN O/P
NEUTRAL
THERMIST0R (NOT ON ALL UNITS)
P4
P1
SEL1
SEL2
FOR R-2000
REMOVE SEL1
TO DISABLE
RECIRCULATION
REMOVE SEL2
DRY
CONTACT
T7
T8
T1
T2
T6
N/C
COMMON
N/O
T15
BLK
SEE MOTOR DETAIL
MICRO PROCESSOR BOARD
DEHUMIDISTAT
P2
P5
INTERNAL
IMPORTANT: Control Low Voltage is 12VAC
DO NOT CONNECT EXTERNAL POWER SOURCES TO UNIT
SEE
DEFROST
DETAIL
WARNING
750 ma
MAX FUSE
FAN MOTOR DETAILS
TI-89A-NE
1106
2
1
P6
RESIDENTIAL WIRING DIAGRAM
LINE
PLUG IN CONNECTOR
AUTO-TRANSFORMER DETAIL
3
2
2
1
1
5
6
4
P3
P6
P3
PIN 1 - BLUE PIN 4 - RED
PIN 2 - YELLOW PIN 5 - WHITE
PIN 3 - BROWN PIN 6 - BLACK
P6
PIN 1 - GREEN
PIN 2 - GREEN
AUTO
TRANSFORMER
Note:
All control connections
are labeled by colour.
Connect to corresponding
colour with low voltage wire
( 20 gauge minimum).
A dry contact closure
between red & black will
initiate high speed override.
CHASSIS
CONTROLAIR 15
YEL
GRN
ORN
RED
BLK
DEFROST DETAILS
PLUG IN
CONNECTOR
P1
BLK
RED
P1
4
3
21
PIN 1 - BLACK
PIN 2 - ORANGE
PIN 3 - RED
PIN 4 - SPARE
PCB PLUG - IN
P1
4
3
2
1
PIN 1 - RED
PIN 2 - ORANGE
PIN 3 - BLACK
PIN 4 - SPARE
PCB PLUG - IN
BI-DIRECTIONAL
DAMPER MOTOR
ORANGE
RED
ORANGE
BLK
95 MAX
155 MAX RX
200 MAX RX
Residential Wiring Diagram For All Models Except 155ECM