Lifebreath 195DCS Air Cleaner User Manual


 
OPTIONS
99-104 Digital Electronic Timer - 20/40/60 min.
99-109 Air Sentry™ Air Quality Monitor designed to accept
remotely mounted Control Pad.
99-250 Ventilation Dehumidistat - Dehumidistat designed to
accept remotely mounted Control Pad.
99-160 Duct Heater w/ Electronic SCR Thermostat, 1 Kw, 7”
(178 mm)
99-161 Duct Heater w/ Electronic SCR Thermostat, 2 Kw, 7”
(178 mm)
99-186 Weatherhoods, Two - 6” (150mm) c/w 1/4” (6mm) mesh
screen
WARRANTY
Units carry a LIFETIME warranty on the heat recovery core and a 5
year replacement parts warranty.
13
49
"
(1245)
STALE AIR
TO OUTSIDE
FRESH AIR
TO INSIDE
14 3/4"
(375)
19"
(483)
Ports
7" (178 mm)
CONDENSATE
DRAINS
BLOWERS
*NOTE: Front clearance of 25 inches (635 mm)
is recommended for servicing unit.
MOTOR
FRESH AIR
FROM OUTSIDE
STALE AIR
FROM INSIDE
FILTER
DEFROST
DAMPER
DEFROST AIR
FROM INSIDE
FILTER
Ports
6" (150 mm)
METAL CLASPS
TI-102-NE
0107
ENGINEERING DATA
THERMALLY CONDUCTIVE, PATENTED ALUMINUM CORE
The cross-flow heat recovery core transfers heat between the two airstreams.
The two cores are arranged for highly efficient counter current airflow.
MOTORS AND BLOWERS
Each air stream has one centrifugal blower driven by a common PSC motor.
5 speed fan operation. 120 VAC, 2.9 Amps.
FILTERS
Washable air filters in exhaust and supply air streams.
MOUNTING THE HRV
Four threaded inserts at corners of case designed to accept four reinforced
polyester straps that are supplied with the unit.
DEFROST
Damper defrost system.
DEHUMIDISTAT
Adjustable Internal Dehumidistat.
CASE
Twenty gauge prepainted galvanized steel (G60) for superior corrosion resis-
tance. Insulated to prevent exterior condensation. Drain connections 2 - 1/2"
(12 mm) OD.
CONTROLS
ControlAir 15 - Standby/ON mode, 20 ON/ 40 OFF mode (each mode has 5
speeds). Control pad can be removed from HRV and remotely mounted.
Weight 106 lbs. (48 kg) Shipping Weight 108 lbs. (49 kg )
Model 300DCS
DIMENSIONS 300DCS inches (mm)
Date: ___________________________________________
Tag: _____________________Qty:___________________
Project: _________________________________________
Engineer: _______________________________________
Contractor: ______________________________________
Supplier: ________________________________________
Quote#:_________________________________________
Submitted by: ____________________________________
Allunits conformto
CSAand ULstandards.
*SensibleEfficiency –thermal **LatentEfficiency –moisture
Note: Effectiveness - based on temp. differential between the 2 airstreams
Efficiency – takes into account all power inputs
Performance (HVI certified)
Netsupply airflow incfm (L/s)against externalstatic pressure
E.S.P
(external static pressure) [cfm (L/s)]
@ 0.1" (25 Pa) 265 (125)
@ 0.2" (50 Pa) 260 (123)
@ 0.3" (75 Pa) 250 (118)
@ 0.4" (100 Pa) 235 (111)
@ 0.5" (125 Pa) 220 (104)
@ 0.6" (150 Pa) 203 (96)
@ 0.7" (175 Pa) 186 (88)
@ 0.8" (200 Pa) 167 (79)
Max. Temperature Recovery 90%
Sensible Effectiveness
@ 119 cfm (56 L/s) 32°F (0°C) 90%
*Sensible Efficiency
@ 119 cfm (56 L/s) 32°F (0°C) 79%
*Sensible Efficiency
@ 125 cfm (59 L/s) -13°F (-25°C) 75%
VAC @ 60HZ 120
WATTS / Low speed. 150
WATTS / High speed 333
Amp rating 2.9
1
2
3
4
5
60
80
100
120
140
160
180
200
220
240
260
280
0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9
Static Pressure (in w.g.)
Air Flow (cfm)
5 - High Speed
*4 - Medium High Speed
*3 - Medium Speed
*2 - Medium Low Speed
*1 - Low speed
* Manufacturers Data