8
41840-A McAlby Court, Murrieta, CA 92562
(800) 451-9343, email: sales@nimbuswater.com
1. System is located where it will not be subject to physical impacts or rough contact by heavy objects.
2. Feed water pressure to the unit is no less than 40 psi and no greater than 80 PSI.
3. Ensure the plasc retainer clip that holds the desalinator cartridge in place is fully engaged and locked in place. The slide
locks must snap into place in the slots. If the clip does not snap easily into place through the slots it means the cartridge is not
fully inserted into the connectors. Press top or boom of cartridge to engage connectors unl it snaps into place properly.
4. All tubing connecons, especially push-in quick connecons, are fully inserted.
5. Tubing connected between the faucet and the drain saddle ng (the ng aached to the sink drain pipe) runs "down-
hill" to the drain. There should be no loops or places where water would not ow out to the drain.
6. Feed water valve is open.
7. Within one to two hours aer inial applicaon of water pressure, check again for leaks especially at the tank, faucet tub-
ing and connectors. These parts will not see full pressure unl approximately 2 hours aer the system is acvated.
8. Flush three tankfuls of product water to drain. If a chlorine scent persists, repeat ushing procedure.