Nimbus Water Systems WM5-50 Water System User Manual


 
8
41840-A McAlby Court, Murrieta, CA 92562
(800) 451-9343, email: sales@nimbuswater.com
1. System is located where it will not be subject to physical impacts or rough contact by heavy objects.
2. Feed water pressure to the unit is no less than 40 psi and no greater than 80 PSI.
3. Ensure the plasc retainer clip that holds the desalinator cartridge in place is fully engaged and locked in place. The slide
locks must snap into place in the slots. If the clip does not snap easily into place through the slots it means the cartridge is not
fully inserted into the connectors. Press top or boom of cartridge to engage connectors unl it snaps into place properly.
4. All tubing connecons, especially push-in quick connecons, are fully inserted.
5. Tubing connected between the faucet and the drain saddle ng (the ng aached to the sink drain pipe) runs "down-
hill" to the drain. There should be no loops or places where water would not ow out to the drain.
6. Feed water valve is open.
7. Within one to two hours aer inial applicaon of water pressure, check again for leaks especially at the tank, faucet tub-
ing and connectors. These parts will not see full pressure unl approximately 2 hours aer the system is acvated.
8. Flush three tankfuls of product water to drain. If a chlorine scent persists, repeat ushing procedure.