Napoleon Fireplaces BGNV40-P Indoor Fireplace User Manual


 
8
W415-0320 / D / 01.06.07
When finishing the fireplace, combustible material may
rest directly on of the top extension.
Note: Maximum weight tolerance is 400 lbs, provided
that it is evenly distributed across the top extensions of
the fireplace.
In order to achieve a countertop or bar type appearance
with the minimum height allowed, framing must be non-
combustible and may be done with metal studding attached
to the top extension sides or the upper frame of the fire-
place. FIGURE 9.
Refer to page 7.
Note: In order to avoid the possibility of exposed
insulation or vapour barrier coming in contact with the
fireplace body, it is recommended that the walls of the
fireplace enclosure be “finished” (ie: drywall/sheetrock),
as you would finish any other outside wall of a home. This
will ensure that clearance to combustibles is maintained
within the cavity.
It is best to frame your fireplace after it is positioned and
the vent system is installed. Use 2x4's and frame to local
building codes. FIGURE 6.
To install the fireplace face flush with the finished wall,
position the framework to accommodate the thickness
of the finished wall.
FIGURE 6
FIGURE 9
FIGURE 7
A = 22 " minus finishing material thickness each side.
FIGURE 8
* The top extension may be removed if non-combustible
framing is faced with a non-combustible material placed
flush with the front face of the unit and extending from the
top of the unit. (Example: cement board) (not supplied).
Combustible counter / bar tops must maintain a minimum
of 38½ inches from the base of the fireplace to the underside
of the top. Figure 7.
NOTE: Wolf Steel trim and/or surround kits will not to-
tally cover the top extension of the fireplace. In order to
obtain a smooth transition from the trim / surround to the
wall, it is recommended that the top extension be re-
moved and the unit be installed following the above pro-
cedure.
TOP EXTENTION
TOP OF THE UNIT
PENINSULA INSTALLATION PROCEDURE
VENTING
FRAMING
COUNTERTOP / BAR INSTALLATION