Napoleon Fireplaces BGD90NT Indoor Fireplace User Manual


 
30
W415-0614 / A / 07.24.07
Main burner goes
out; pilot goes out.
Main burner goes
out; pilot stays on.
Pilot fl ame is not large enough
or not engulfi ng the thermo-
pile
- turn up pilot fl ame.
- replace pilot assembly.
Thermopile shorting
- clean thermopile connection to the valve. Reconnect.
- test and replace thermopile if required.
Temperature setting on trans-
mitter is satisfi ed
- turn up temperature setting.
Pilot goes out while
standing; Main
burner is in ‘OFF’
position.
Pilot burning; no
gas to main burner;
Flame height is on
‘HI’; Remote and
transmitter ON
Remote receiver
- disconnect switch wires &connect a jumper wire across terminals
1 & 3; if the main burner lights, check the wires for defects and / or
replace wires.
Main burner orifice is
plugged.
- remove stoppage in orifi ce.
Faulty thermopile.
- test and replace if required.
Gas piping is undersized.
- turn on all gas appliances and see if pilot fl ame fl utters, diminishes or
extinguishes, especially when main burner ignites. Monitor appliance
supply working pressure.
- check if supply piping size is to code. Correct all undersized piping.
Refer to “MAIN BURNER GOES OUT; PILOT STAYS ON”
Vent is blocked
Vent is re-circulating
- check for vent blockage.
- check joint seals and installation.
8” fl exible vent has become
disconnected from fi replace.
- re-attach to fi replace.
Pilot will not light. - check if pilot can be lit by a match
- check that the wire is connected to the spark module.
- check batteries.
- replace the wire if the wire insulation is broken or frayed.
- replace the electrode if the ceramic insulator is cracked or broken.
- replace spark module.
No spark at pilot burner
- fi ll the tank.
Out of propane gas
Spark gap is incorrect - spark gap should be 0.150” to 0.175” (5/32” to 11/64” approx.) from
the electrode tip and the pilot burner. To ensure proper electrode loca-
tion, tighten securing nut (fi nger tight plus 1/4 turn).
No gas at the pilot burner
- check that the manual valve is turned on.
- check the pilot orifi ce for blockage.
- call the gas distributor.
SYMPTOM PROBLEM TEST SOLUTION
PILOT
BURNER
THERMOCOUPLE
THERMOPILE