Napoleon Fireplaces BGD90NT Indoor Fireplace User Manual


 
14
W415-0614 / A / 07.24.07
FIGURE 30
MANTLE CLEARANCES
0
34 7
8
9
12 56
7
H
E
I
G
H
T
M
A
N
T
L
E
MANTLE WIDTH
5
6
4
3
Combustible mantle clearance can vary according to the
mantle depth. Use the graph to help evaluate the clearance
needed.
Do NOT use the fireplace if any part has been under
water.
Call a qualified service technician IMMEDIATELY to
have the fireplace inspected for damage to the electri-
cal circuit.
If access to the control area is necessary BEFORE IN-
STALLATION, remove the access panel. Located along
the right side of firebox.
The access panel must be re-installed before operating
the unit.
It is necessary to hard wire this fireplace.
Permanently framing the fi replace with an enclosure, requires
the fi replace junction box to be hard wired.
This fi replace must be electrically connected and grounded in
accordance with local codes. In the absence of local codes,
use the current CSA C22.1 CANADIAN ELECTRICAL CODE
in Canada or the ANSI/NFPA 70-1996 NATIONAL ELECTRI-
CAL CODE in the United States.
ELECTRICAL CONNECTION
HARD WIRING CONNECTION
SCHEMATIC
FIGURE 31
IN
OUT
O
F
F
P
I
L
O
T
O
N
LIGHT FAN
L2
L1
[HOT]
TP
TH
AUX
FAN LINE
VALVE
MOTOR AUTO MAN
GAS
VALVE
REMOTE RECEIVER