Turn off all gas to the fireplace.
Open windows.
Do not try to light any appliance.
Do not touch any electric switch; do
not use any phone in your building.
Immediately call your gas supplier from
a neighbour's phone. Follow the gas supplier's instruc-
tions.
If you cannot reach your gas supplier, call the fire de-
partment.
L
ON/OFF
KNOB
F
F
O
P
I
N
O
L
O
T
I
H
PILOT
O
P
I
L
O
T
ADJUSTMENT
KNOB
FLAME
When lit for the first time, the fireplace will emit a slight
odour for a few hours. This is a normal temporary condi-
tion caused by the curing of the logs and the "burn-in" of
internal paints and lubricants used in the manufacturing
process and will not occur again. Simply open a window to
sufficiently ventilate the room.
After extended periods of non-operation such as following
a vacation or a warm weather season, the fireplace may
emit a slight odour for a few hours. This is caused by dust
particles in the heat exchanger burning off.
Purge the gas line with a glass door open. Assure that
a continuous gas flow is at the burner before re-install-
ing the door.
A. This fireplace is equipped with a pilot which must be lit
by hand while following these instructions exactly.
B. Before operating smell all around the fireplace area for
gas and next to the floor because some gas is heavier
than air and will settle on the floor.
C. Use only your hand to turn the gas control knob. Never
use tools. If the knob will not turn by hand, do not try to
repair it. Call a qualified service technician. Force or at-
tempted repair may result in a fire or explosion.
D. Do not use this fireplace if any part has been under
water. Immediately call a qualified service technician to
inspect the fireplace and replace any part of the control
system and any gas control which has been under water.
WARNING: The gas valve has an interlock device which
will not allow the pilot burner to be lit until the thermocou-
ple has cooled. Allow approximately 60 seconds for the
thermocouple to cool.
When lighting and re-lighting, the gas knob cannot be
turned from pilot to off unless the knob is depressed
slightly.
1. Stop! Read the above safety information on this label.
2. Turn off all electric power to the fireplace.
3. Turn the gas knob clockwise to off.
4. Wait five (5) minutes to clear out any gas. If you smell
gas including near the floor. Stop! Follow "B" in the
above safety information on this label. If you don't smell
gas go the next step.
5. Turn gas knob counter-clockwise to pilot.
6. Depress slightly and hold gas knob while lighting the
pilot with the push button ignitor. Keep knob depressed
for one minute, then release. If pilot does not continue
to burn, repeat steps 3 through 5.
7. With pilot lit, depress and turn gas knob counter-clock-
wise to on.
8. If equipped with remote on-off switch/thermostat, main
burner may not come on when you turn valve to on.
Remote switch must be in the on position to ignite
burner.
9. Turn on all electric power to the fireplace.
1. Turn off all electric power to the fireplace if service is to be
performed.
2. For a complete shut-down procedure: push in gas control
knob slightly and turn clockwise to off. Do not force.
3. For a temporary shut-down procedure: set thermostat to
lowest setting or remote switch to off. Press and turn the
gas knob clockwise to pilot.
Turn off the gas and electrical power before servicing the
fireplace.
CAUTION: Label all wires prior to disconnection when servic-
ing controls. Wiring errors can cause improper and dangerous
operation. Verify proper operation after servicing. This fireplace
and its venting system should be inspected before use and at
least annually by a qualified service person. The fireplace area
must be kept clear and free of combustible materials, gasoline
or other flammable vapours and liquids. The flow of combus-
tion and ventilation air must not be obstructed.
1. In order to properly clean the burner and pilot assembly,
remove the logs to expose both assemblies.
2. Keep the control compartment, logs, burner, air shutter open-
ing and the area surrounding the logs clean by vacuuming or
brushing, at least once a year.
3. Check to see that all burner ports are burning. Clean out any
of the ports which may not be burning or are not burning prop-
erly.
4. Check to see that the pilot flame is large enough to engulf
the thermocouple and thermopile and reaches toward the
burner with the third jet.
5. Replace the cleaned logs.
6. Check to see that the main and runner burners ignite com-
pletely on all openings when the gas knob for the burners is
turned on. A 5 to 10 second total light-up period is satisfactory. If
ignition takes longer, consult your Napoleon dealer / distributor.
7. Check that the gasketing on the sides, top and bottom of
the door is not broken or missing. Replace if necessary.
OPERATION / MAINTENANCE
FOR YOUR SAFETY READ BEFORE LIGHTING:
WHAT TO DO IF YOU SMELL GAS:
LIGHTING INSTRUCTIONS
TO TURN OFF GAS
P
I
N
O
L
O
T
F
F
O
GAS KNOB
MAINTENANCE