ARMING AWAY: SETTING THE ALARM WHEN LEAVING
System Trouble If you attempt to arm with the SYS TBL light on, a 3-second tone will
sound and a “P” will display in the window. This indicates that the system has detected
a problem which may prevent it from operating properly. A number corresponding to the
trouble will then appear in the display. Refer to SYSTEM TROUBLE ERROR CODES
for descriptions of these troubles. If you cannot correct the problem immediately, press
C and you will then be able to arm the system in this condition. Note: If you
cannot clear the trouble, have the system checked as soon as possible.
Area Arming (Optional)
In a system that has been partitioned into multiple areas, one or more areas may be armed while others remain disarmed.
Manager's Mode.
The Manager's Mode allows the user to arm / disarm other areas in a partitioned system. To arm a different area:
1. Press the numerical key representing the other area number.
2. Press
G followed by U. The keypad will now provide status and control of that area.
3. Enter your code followed by
Q to arm.
4. Press
G followed by U to return to the home area.
Global Arming (Optional) (GEM-P3200/9600 panels only).
To arm all areas simultaneously (including the area you are in), press 9, G and enter your code followed by U.
To disarm all areas simultaneously, press
0, G and enter your code followed by U.
The User Code must be valid in all area(s).
If any zone is not secured, the keypad will display “P”. All faulted zones in the respective area(s) must be secured or
bypassed. Note: If a system trouble is indicated, the system cannot be armed using this method.
P
INTERIOR
BYPASS FIRE/TBL SYS TBL CHIME