PAGE 18 — MQ-D206H DIAPHRAGM PUMP — PARTS MANUAL — REV. #0 (12/15/03)
6. Grasp the starter grip (Figure 13) and slowly pull it out. The
resistance becomes the hardest at a certain position, corre-
sponding to the compression point. Pull the starter grip briskly
and smoothly for starting.
Figure 13. Starter Grip
MQ-D206H — INITIAL START-UP (ENGINE)
Starting the Engine (
HONDA
engine)
1. Place the engine
fuel valve lever
(Figure 8) to the "ON"
position.
DO NOT attempt to operate the pump until the Safety, General
Information and Inspection sections of this manual have been
read and thoroughly understood
.
2. Move the
throttle lever
(Figure 9) away from the slow
position, about 1/3 of the way toward the fast position.
Figure 8. Engine Fuel Valve Lever (ON Position)
Figure 9. Throttle Lever (1/3 Start Position)
3. Place the
choke lever
(Figure 10) in the "OPEN " position if
starting a
cold
engine.
4. Place the
choke lever
(Figure 9) in the "CLOSED " position
if starting a
warm engine
or the
temperature is warm.
Figure 10. Engine
Choke Lever (Open)
Figure 11. Engine Choke Lever (Closed)
5. Place the
engine ON/OFF switch
(Figure 12) in the "ON "
position.
Figure 12. Engine ON/OFF Switch (ON Position)
This section is intended to assist the operator with the
initial
start-up
of the trash pump. It is extremely important that this
section be read carefully before attempting to use the pump in
the field.
CAUTION :