Gear Reduction Oil (Transmission)
1. Remove the transmission oil level plug (Figure 6). If oil
begins to seep out as the plug is being removed, then it
can be assumed that the transmission oil is at the proper
operating level.
2. If oil does not seep out as the oil level plug is being removed,
then remove the transmission oil fill plug and fill with
SAE 80/90
EP gear oil
to the proper operating level.
Transmission oil capacity is capacity is 1-1/4 pints (590 ml.).
MQ-D206H— PRE-SETUP (PUMP)
Connecting Rod Bearing Lubrication
1. Grease connecting rod bearing thru the acess hole
(Figure 7) every 25 hours of operation.
2. Use only
premium lithium based grease
, conforming to
NLG1 Grade #2 consistency.
Figure 6. Transmission Oil Level
Figure 7. Connecting Rod Bearing Lubrication
Helpful Hints
The capacity of this diaphragm pump will vary greatly depending on
the height of the suction lift and length of the discharge hose. A
discharge hose which is too small, long or high will cause the
following:
Excessive bulging of diaphragm on the down stroke.
Valves closing with a lould snap.
Rough operation.
Engine overloads and slow downs.
Reduced efficiency
NOTE
Diaphragm pumps will handle fluids
containing considerable solids (not to
exceed 1.00 inch/25 mm), however, if
the mixture is too heavy to be pumped,
water must be added until the mixture