Mr. Heater MHVFB10LP Fan User Manual


 
11
Installation Instructions and Owner’s Manual
Unvented LP-Gas Fired Buddy Wall-Mount Heater
Make sure grille guard is in place before running
heater. If screen or grille guard is removed for servic-
ing it must be replaced prior to operating the heater.
WARNING: Failure to keep the primary air
opening(s) of the burner(s) clean may result in soot-
ing and property damage.
CLEANING ODS/PILOT AND BURNER
• Use as vacuum cleaner, pressurized air or
small soft bristled brush to clean.
CLEANING BURNER PILOT AIR HOLE INLET
We recommend that you clean the unit ever 2,500
hours of operation or every three months. We also
recommend that you keep the burner tube and pilot as-
sembly clean and free of dust and dirt. To clean these
parts we recommend using compressed air no greater
than 30 psig.
This can be done by using a vacuum cleaner in the
blow position, using compressed air in a can, please
follow the directions on the can. If you don’t follow
directions on the can you could damage the burner or
pilot assembly. In addition, the directions that follow
should also be followed.
1. Shut off the unit, including the pilot. Allow the
unit to cool for at least thirty minutes.
2. Inspect burner and pilot for dust and dirt.
3. Blow air through the port/slots and holes in the
burner.
A yellow tip on the pilot ame indicates dust and dirt
in the pilot assembly. To clean the pilot assembly nd
the small pilot air inlet hole about two inches from
where the pilot ame comes out of the pilot assembly
(see Pilot Air Inlet Hole in gure 25). With the unit off,
lightly blow air through the air inlet hole. You may blow
through a drinking straw if compressed air is not avail-
able.
Figure 25
CLEANING HEATER CABINET
Air passageways
• Use a vacuum cleaner or pressurized air to
clean exterior
• Use a soft cloth dampened with a mild soap
and water mixture. Wipe the cabinet to remove
dust.
SPECIFICATIONS
MHVFB10LP
BTU (Available) 10,000
Type of Gas LP-Gas Only
Ignition Piezo
Pressure Regulator Setting 10 Inches of
Water
Inlet Gas Pressure (Maximum) 14 Inches of
Water
Inlet Gas Pressure (Minimum) 11 Inches of
Water
Burners / Orice nozzles 1
Thermostatic Control No
Clearances: inches (mm)
Top 36” (915cm)
Sides 6” (152cm)
Floor (min. to top of carpet) 2” (51cm)
Fabric / ammable objects 36” (915cm)