Morphy Richards Hand held vacuum cleaner Vacuum Cleaner User Manual


 
Dust disposal
To obtain the best results from your
cleaner be sure to check and empty the
dust compartment regularly, otherwise
the airflow and cleaning power will be
reduced and you may damage your
cleaner.
1 Ensure the cleaner is switched off and
disconnected from the mains supply.
2 Hold over a dustbin and press in the
dust compartment release button , the
dust compartment door will automatically
drop down. Shake the vacuum to release
the dirt and make sure it is completely
empty. I
Hepa Filter cleaning
Warning: The dust compartment must
be emptied BEFORE the Hepa filter is
removed. Every time you empty the
cleaner the Hepa filter must be
cleaned.
1 Once the dust compartment is empty,
remove the pleated hepa filter Ô and
mesh filter by pushing the tab to
release. J
2 Pull the pleated hepa filter Ô out of the
mesh filter cover and clean both by
gently brushing over the dustbin. Wash
the filters regularly in warm water. K
Leave to air dry thoroughly before
replacing into the cleaner.
DO NOT USE DETERGENTS
3 Replace the pleated
filter into the mesh
filter cover
Making sure the yellow
tab on the Hepa Filter
moulding is adjacent to
the clip on the mesh
filter cover
LL
and replace
back into the cleaner. Ensure the hepa filter
is securely fitted back into place.
Blocked filters will reduce the airflow to
the motor, should the airflow become
substantially blocked, the product will
then be liable to overheat and the
thermal fuse will activate. Should this
activate, the product will stop functining,
unplug the product and allow it to cool
down (ths can take between 30-40
minutes depending on the ambient
temperature conditions).
Inserting Hepa Filter M
Warning: Make sure that the Hepa filter
has been placed in correctly.
DO NOT USE THE PRODUCT WITHOUT
THE HEPA FILTER FITTED
.
IMPORTANT
All filters should be checked regularly for
signs of damage, preferably after each
cleaning task. The filters must be
replaced immediately if they become
I
J
K
L
M
6