Monessen Hearth TPB30 Electric Heater User Manual


 
30 70D0004
In normal operation at full rate after 15 minutes, the following ame appearances should be observed:
Figure 35 - Correct Appearance of Rear Flames of Charred Timber
Burner will have a random pattern of yellow flames as shown in Figure 35. There should be glowing embers on the front
burner. Note: The front ames and embers will be an opaque orange color during the burn off time.
OPERATING INSTRUCTIONS
Avoid any drafts that alter burner ame patterns. Do not allow fans to blow directly into the fireplace. Do not place
a blower inside the burn area of the firebox. Ceiling fans may create drafts that alter flame patterns. Sooting and improper
burning will result.
During manufacturing, fabricating and shipping, various components of this appliance are treated with certain oils, films or
bonding agents. These chemicals are not harmful, but may produce annoying smoke and smells as they are burned off during
the initial operation of the appliance, possibly causing headaches or eye or lung irritation. This is a normal and temporary
occurrence.
The initial break-in operation should last six hours with the burner at the highest setting. Provide maximum ventilation by
opening windows or doors to allow odors to dissipate. Any odors remaining after this initial break-in will be slight and will
disappear with continued use.
This appliance must not be used with glass doors in the closed position. This can lead to pilot outages and severe sooting
outside the fireplace. See Figure 3, page 10.