Monessen Hearth LSTF36 Indoor Fireplace User Manual


 
79D0004 7
CLEARANCES and HEIGHT REQUIREMENTS
CLEARANCES and HEIGHT REQUIREMENTS
Ensure that minimum clearances shown in Figures 3 through 7 are maintained. Left and right clearances are determined
when facing the front of the firebox.
Follow these instructions carefully to ensure safe installation. Failure to follow these requirements may create a
fire hazard.
1. Sidewall Clearances — The clearance from the inside of the appliance to any combustible adjacent wall should not
be less than 2
7
/8". Refer to Figure 3.
2. Ceiling Clearance — The ceiling must be at least 42" from the top of the firebox opening (bottom of hood). Refer
to Figure 3.
3. Back Wall Clearance — The appliance may be placed against a combustible back wall.
4. Parallel Wall Clearance — The clearance from the opening of the firebox to any wall that is parallel to the opening
should not be less than 36" (LSTF36 and LPF36 models only). Refer to Figure 4.
Figure 3 - Sidewall and Ceiling Clearances
Figure 4 - Parallel Wall Clearance
(LSTF36 and LPF36 Models Only)
Figure 5 - Minimum Hearth Dimensions
AB C
See-Thru 33 3/16" 27 3/4" 21 15/16"
Corner 35 5/16" 27 3/4" 21 15/16"
Peninsula 35 5/16" 27 3/4" 21 15/16"
Minimum Hearth Dimensions
5
5
/8"
42"
36"
C
A
B