Monessen Hearth KHLDV400 Indoor Fireplace User Manual


 
73D0024
5
KHLDV Series Gas Fireplace

This appliance has been certified for use
with either natural or propane gas. See
appropriate data plates.
This appliance is not for use with solid
fuels.
The appliance is approved for bedroom or
bedsitting room installations.
The appliance must be installed in accor-
dance with local codes if any. If none exist
use the current installation code. ANSI
Z223.1/NFPA 54 in the USA, CSA B149 in
Canada.
This appliance is mobile home approved.
The appliance must be properly connected
to a venting system.
The appliance is not approved for closet or
recessed installations.
FP2124
KHLDV controls
Off/Pilot/On Knob
Figure 1 -
KHLDV Series Fireplace
(shown with Millivolt)
Hi/Lo Knob
On/Off/RS Switch
Ignitor
Light Control
Blower Control
(optional)
Access Panel
FP2124


Input ratings are shown in BTU per hour and are certified
without deration for elevations up to 4,500 feet (1,370
m) above sea level.
For elevations above 4,500 feet (1,370 m) in USA,
installations must be in accordance with the current
ANSI Z223.1/NFPA 54 and/or local codes having juris-
diction.
In Canada, please consult provincial and/or local authori-
ties having jurisdiction for installations at elevations
above 4,500 feet (1,370 m).
Natural Propane (LP)
Inlet Minimum 4.5” w.c. 11.0” w.c.
Inlet Maximum 10.5” w.c. 13.0” w.c.
Manifold Pressure 3.5” w.c. 10.0” w.c.

 
   
KHLDV400NV Nat. 40,000 28,500
KHLDV400PV Lp 40,000 30,500
KHLDV400NTSC Nat. 40,000 28,500
KHLDV400PTSC LP 40,000 30,500
KHLDV500NV Nat. 50,000 35,500
KHLDV500PV LP 50,000 38,500
KHLDV500NTSC Nat. 50,000 35,500
KHLDV500PTSC LP 50,000 38,500

   
KHLDV400 Nat. #49 (.073") #35 (.110" )
KHLDV400 LP #56 (.0465") #52 (.0635")
KHLDV500 Nat. 2.3 mm #30 (.1285)
KHLDV500 LP #55 (.052") #50 (.070")