Monessen Hearth IDV380PVC Indoor Fireplace User Manual


 
57D0016
IDV380/IDV490 Fireplace Insert
11

    
  
       
      
    




Consult local building codes before beginning the instal-
lation. The installer must make sure to select the proper
vent system for installation. Before installing vent kit,
the installer must read this insert manual and vent kit
instructions.
Only a qualified installer/service person should install
venting system. The installer must follow these safety
rules:
Wear gloves and safety glasses for protection.
Use extreme caution when using ladders or when
on rooftops.
Be aware of electrical wiring locations in walls and
ceiling.
The following actions will void the warranty on your vent-
ing system:
Installation of any damaged venting component.
Unauthorized modification of the venting system.
Installation of any component part not manufac-
tured or approved by MHSC.
Installation other than permitted by these instruc-
tions.
      
    
     
     
    







      

Figure 6
 


The exhaust vent must reline the entire length of
chimney and terminate above chimney top.
Vent must meet all vent manufacturer's requirements
when installed.
Make sure you have the following before installing
unit:

3" and 3" UL 1777 Listed gas liner for air inlet and
exhaust.
Vertical termination kit (AI31TK33A)

4" and 3" UL 1777 Listed gas liner for air inlet and
exhaust.
Vertical termination kit (AI4TK43A)

FP2625
typical venting
Exhaust
Inlet
Maximum 1"
(305 mm) Offset at
Base of Insert
Maximum
Height
40' (1.9 m)
Minimum
Height
10' (3 m)
FP65
Figure 7 -
Venting Unit