Monessen Hearth HDV500NV/PV Indoor Fireplace User Manual


 
HDV Series Direct Vent Gas Fireplace
3
56D3048

You may check for gas leaks with the following
methods only:
Soap and water solution
An approved leak testing spray
Electronic sniffer
NOTE: Remove any excessive pipe
compound from the connections.
Excessive pipe compound can set off
electronic sniffers.
1. Depress and turn knob counterclockwise
to pilot position.
. Depress fully and hold pilot gas knob. Depress piezo
ignitor as many times as needed to ignite the pilot.
Keep knob fully depressed for a few seconds.
Release and check that pilot continues to
burn.
If the pilot does not stay lit, repeat steps 1 and .
Figure 45 -
Pilot Position
Check for gas leaks in each of the following locations:
Pipe from the gas supply line connection to the gas valve
Burner connections Field made joints / gas shutoff valve
Pilot Factory made joints
Each joint or connection All joints on valve and control body




      




PILOT
O
F
F
P
I
L
O
T
O
N
FP1935
control knob pilot
