Monessen Hearth HBDV400N/PSC7 Indoor Fireplace User Manual


 
HBDV7 Series Direct Vent Gas Fireplace
54D8000
9
Figure 6 -
Secure Fireplace to Floor and Framing Studs

The fireplace must be secured to the floor and/or to framing studs as shown in Figure 6. Use
two () wood screws or masonry/ concrete screws to secure fireplace to the floor. Use four (4)
screws to attach fireplace to framing. The side nailing flanges are 1/" or 5/8" to accommodate
different wall thickness.
FP2583
secure fireplace
Insulation
Board
Screws
Nailing Flange
Screws
Framing
Nailing
Flange
Screws
FP583

 Any remote wiring (i.e. remote control, wall switch, and optional fan) must be done prior to
final finishing to avoid costly reconstruction.
Only noncombustible materials (i.e. brick, tile, slate, steel, or other materials with a UL fire rating
of Zero) may be used to cover the black surface of the appliance. A 300°F minimum adhesive may
be used to attach facing materials to the black surface. If joints between the finished wall and the
fireplace surround are sealed, a 300°F minimum sealant material (General Electric RTV103 or
equivalent) must be used.
Screws



