Monessen Hearth EYF24 Indoor Fireplace User Manual


 
65D1009 27
HI
LO
HI
LO
HI
LO
WARNING
OPERATING INSTRUCTIONS
MANUAL CONTROL LIGHTING INSTRUCTIONS
TO TURN OFF HEATER
1. Turn control knob clockwise to OFF position to completely shut off the heater.
2. If applicable: Turn off all electric power to the heater.
1. STOP! Read the safety information.
2. Make sure the manual shutoff valve is fully open.
3. This heater is equipped with an ignition device (piezo) which automatically lights the pilot.
4. See Figure 35, page 26 for the location of the piezo ignitor and control knob. Push in gas control knob slightly
and turn control knob clockwise
to the OFF position.
NOTE: Knob cannot be turned to OFF unless knob is pushed in slightly. Do not force.
5. Wait 5 minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas STOP! Fol-
low the instructions under
What to Do if You Smell Gas, page 26. If you do not smell gas, go to the next step.
6. From OFF position, push in gas control knob slightly and turn counterclockwise
to the IGN posi-
tion. Figure 36. Push in and hold control knob for 5 seconds.
NOTE: If you are running the heater for the first time, it will be necessary to press in the control knob for
30 seconds to allow air to bleed out of the gas piping.
7. With the control knob pushed in, push and release the piezo ignitor button to light the ODS pilot. The pilot
is located behind the front log and front burner. If piezo ignitor does not light the pilot, see
Match Lighting
Instructions
, page 29.
8. Hold the control knob in for an additional 10 seconds to prevent the ODS pilot from shutting off the gas
while the thermocouple is warming up.
9. Release the control knob.
• If the knob does not pop out when released, stop and immediately call your service technician or gas sup-
plier.
If the ODS pilot will not stay lit after several tries, push and turn the gas control knob clockwise
to OFF and wait 15 seconds. Repeat steps 6 through 9.
10. Push in control knob and turn counterclockwise
to the HIGH setting. At this location the control
knob will pop out when positioned correctly. The knob can now be positioned at any position between HIGH
and LOW. See Figures 37 and 38.
Wait 30 seconds before readjusting
the heater when the control knob has
been turned down to a lower setting.
WARNING
Push
Push
Rotate
Rotate
Rotate
Figure 36 - IGN Position
Figure 37 - HIGH Position Figure 38 - LOW Position