Monessen Hearth CSDV30DNV Stove User Manual


 
16
58D6056
CSDV Series Direct Vent Gas Stove

9Z\x"
(241 mm)
9Z\x"
(241 mm)

Framing Detail

7Z\x"
(190 mm)
VO584-100
VO584-100
Vent Opening
2/99 djt
Figure 17 -
Locate Vent Opening on Wall
HOT
FP1955
horizontal vent cap
Vent Cap
Wood Screw
Apply Mastic to
All Four Sides
Figure 18 -
Install Horizontal Vent Cap
FP1955
HOT
FP1956
vinyl siding standoff
Apply Mastic to
All Four Sides
Cut Vinyl Siding
Away to Fit Standoff
Wood
Screw
Vent
Cap
Bolt
Nut
Standoff
FP1956
Figure 19 -
Install Vinyl Siding Standoff

      


5. Slide the wall thimble over the vent pipe before con-
necting the horizontal run to the vent cap. Figure 20
6. Carefully move the stove with vent assembly attached
toward the wall and insert the vent pipe into the hori-
zontal termination. The pipe overlap should be a mini-
mum of 1Z\v" (32 mm). Apply silicone to the outer pipe
connection. Fasten all vent connections with screws
provided.
7. Slide the wall thimble against the interior wall surface
and attach with screws. Figure 20
FP1957
install firestop
Interior Wall
Surface
Decorative
Wall Thimble
Horizontal
Vent Pipe
Screw
Vent Cap
(Horizontal
Termination)
FP1957
Figure 20 -
Connect Vent Cap with
Horizontal Vent Pipe


Figures 21 through 23 show different configurations for
venting and horizontal termination. Each figure includes a
chart with an example of horizontal maximum and vertical
minimum dimensions taken from the chart on Page 14.
 The horizontal run controls the mini-
mum vertical height (i.e. the longer the hori-
zontal run, the higher the termination will be).
Follow the chart on Page 14. All horizontal terminations
require a 1/4" (6 mm) rise per 12" (305 mm) of horizontal
run.