Monessen Hearth CDVR36 Indoor Fireplace User Manual


 
69D0023 31
#1 #2 #3 #4 #5 #6 7#
Electronic Valve
GRAY #7
RED #2
RED #2
BLACK #4
GREEN #6
BLUE #1
BLUE
YELLOW
YELLOW
WHITE #3
MAGENTA #5
15’ Wall Switch Wire
BLACK
WHITE
Switch
RS
OFF
ON
Transformer
Secondary
24V
WHITE
WHITE
GREEN
BLACK
BLACK
Primary - 120V
To Junction Box
Pilot Assembly
Spark
Sense
Ignition Module (Synetek)
HI
LO
EV1 EV2
ELECTRICAL INSTALLATION
ELECTRONIC PILOT IGNITION WIRING
REMOTE WALL SWITCH
Position the wall switch. Do not extend beyond the
15 feet of wire.
OPTIONAL DC REMOTE SYSTEMS
See section entitled Hearth Mount in the Millivolt
hand held remote instructions supplied with the
remote.
1. Using a flat head screw driver, bend the “remote”
tabs up from the bottom of the fireplace. See
Figure 40.
2. Follow the instructions on remote control to snap
the remote cover plate to the remote receiver
3. Connect the wire terminal from the remote
receiver. This replaces the 15' wall switch con-
nection to the switch. See Figure 39.
4. Use the screws that came with the remote control
to mount the remote receiver cover to the bent
up “remote” tabs. See Figure 40.
Figure 39 - Remote Wall Switch Wiring Diagram
Remote Control
Figure 40 - Remote Control Location
“Remote” Tabs
WARNING
Do not connect 110-120 VAC to the
Remote Wall Switch. The appliance
will malfunction.