Model name Indoor unit
PCA-A24KA PCA-A30KA PCA-A36KA PCA-A42KA
Outdoor unit
PUY-A24NHA3-BS
PUY-A24NHA3
PUY-A30NHA3-BS
PUY-A30NHA3
PUY-A36NHA3-BS
PUY-A36NHA3
PUY-A42NHA3-BS
PUY-A42NHA3
Cooling Max. Capacity Btu/h 24
,
000 30
,
000 35
,
000 42
,
000
Rated Capacity Btu/h 24
,
000 30
,
000 35
,
000 42
,
000
Min. Capacity Btu/h 12
,
000 12
,
000 12
,
000 18
,
000
Total Input W 2340 3760 4630 4110
EER Btu/h/W 10.3 8.0 7.6 10.2
SEER Btu/h/W 16.8 14.5 14.4 15.8
Moisture Removal Pints/h 5.8 8.3 8.5 11.7
*1SHF 0.73 0.69 0.73 0.69
Heating Max. Capacity Btu/h
----
Rated Capacity Btu/h
----
Min. Capacity Btu/h
----
Total Input W
----
COP W/W
----
*1HSPF (/) Btu/h/W
----
Heating Rated Capacity Btu/h
----
at low ambient Total Input W
----
*2COP W/W
----
Power supply Phase
,
Cycle
,
Voltage 1phase
,
60Hz
,
208/230V
Breaker size A 25 30
Voltage Indoor - Outdoor S1-S2 AC 208 / 230V
Indoor - Outdoor S2-S3 DC24V
Indoor - Remote Controller DC12V
Indoor unit MCA A 1 2
MOCP A 15
Fan Motor F.L.A. 0.54 0.97
Fan Motor Output W 95 160
Air flow DRY CMM 15-16-17-19 22-24-26-28
(
Lo-M2-M1-Hi
)
WET CMM 14-15-16-18 20-22-24-26
Air flow DRY CFM 530-565-600-670 775-850-920-990
(
Lo-M2-M1-Hi
)
WET CFM 495-530-565-635 705-775-850-920
External pressure Pa 0
Sound level dB
(
A
)
33-35-37-40
16-17-18-20
15-16-17-19
565-600-635-705
530-565-600-670
35-37-39-41 37-39-41-43
23-25-27-29
21-23-25-27
810-885-955-1025
740-810-885-955
39-41-43-45
(
Lo-M2-M1-Hi
)
External finish
(
Panel
)
White Munsell 6.4Y 8.9/0.4
Dimension W : mm [inch] 1600 [63]1280 [50-3/8]
Unit
(
Panel
)
D : mm [inch] 680 [26-3/4]
H : mm [inch] 230 [9-1/16]
Weight kg 32 36
Unit
(
Panel
)
lbs 71 79
38
84
Field drain pipe size O.D.
mm [inch] 26 [1-1/32]
Remote Controller Attached in Indoor Unit
Outdoor unit MCA A 18 25 26
MOCP A 30 40
Fan Motor F.L.A. 0.75 0.4 + 0.4
Fan Motor Output W 75 86 + 86
Compressor TNB220FLHM ANV33FDPMT
R.L.A 12 20
L.R.A. 14 17.5 27.5
Air flow CMM [CFM] 55 [1
,
940] 100 [3
,
530]
Refrigerant Control Linear Expansion Valve
Defrost Method
-
Sound level at cooling
dB
(
A
)
48 51
Sound level at heating
dB
(
A
)
--
External finish Ivory Munsell 3Y 7.8/1.1
Dimension W : mm [inch] 950 [37-3/8]
D : mm [inch] 330+30 [13 + 1-3/16]
H : mm [inch] 943 [37-1/8] 1350 [53-1/8]
Weight kg [lbs]
kg [lbs]
74[163] 117 [258]
Refrigerant Type R410A
Charge 3.0 [6 lbs 10 oz] 4.5 [10 lbs]
Oil L [oz] 0.87
(
FV50S
)
[28] 1.4
(
FV50S
)
[45]
Refrigerant pipe size Gas side O.D. mm [inch] 15.88 [5/8]
Liquid side O.D. mm [inch] 9.52 [3/8]
Refrigerant pipe length Height difference Max. 30m [Max. 100ft]
Length Max. 50m [Max. 165ft]
Refrigerant Piping Not Supplied
Connection Method Flared
2-3. CEILING-SUSPENDED TYPE
NOTES : *1.Rating conditions (cooling)-Indoor : D.B. 26.7(80°F), W.B. 19.4(67°F) Outdoor : D.B. 35(95°F), W.B. 23.9(75°F)
(heating)-Indoor : D.B. 21.1(70°F), W.B. 15.6(60°F) Outdoor : D.B. 8.3(47°F), W.B. 6.1(43°F)
*2.Rating conditions(heating)-Indoor : D.B. 21.1(70°F), W.B. 15.6(60°F) Outdoor : D.B. -8.3(17°F), W.B. -9.4(15°F)
Operating range
Indoor intake air temperature
D.B. 35(95°F), W.B. 21.7(71°F)
D.B. 19.4(67°F), W.B. 13.9(57°F)
D.B. 26.7(80°F), W.B. 19.4(67°F)
D.B. 21.1(70°F), W.B. 15.6(60°F)
Outdoor intake air temperature
D.B. 46(115°F)
D.B. -18(0°F)*
D.B. 21.1(70°F), W.B. 15(59°F)
D.B. -11.1(12°F), W.B. -12.2(10°F)
Cooling
Heating
Maximum
Minimum
Maximum
Minimum
* In case that the wind baffle is installed. (In case that the wind baffle is not installed, the minimum temperature will be -5(23°F)DB.)