–25–
Installation location setting
1
If the air conditioning unit is running, press the ON/
OFF button to stop.
The installation location setting cannot be made while the unit is running.
■ Take the air conditioning unit’s location into account and adjust the left/right airflow range to maximize air-conditioning.
(Center Installation)
2
Press the AIR FLOW U/D (UP/DOWN) button and the
AIRFLOW L/R (LEFT/RIGHT) button together for 5
seconds or more.
The installation location display illuminates.
3
Setting the air-conditioning installation location.
Press the AIR FLOW L/R (LEFT/RIGHT) button and adjust to the desired
location.
Each time the AIR FLOW L/R (LEFT/RIGHT) button is pressed, the display
is switched in the order of:
(Right End Installation) (Left End Installation)
4
Press the ON/OFF button.
The air-conditioner's installation location is set.
Press within 60 seconds of setting the installation location (while the instal-
lation location setting display illuminates).
Press within
60 sec.!
The diagram below indicates the airflow ranges corresponding to the air-conditioner's installation location. Consider your room's
layout and set the airflow range to maximize conditioning effectiveness.
Air conditioner installation location and airflow range
Airflow range Airflow range Airflow range
(Left End Installation) (Center Installation) (Right End Installation)
• Once the installation location setting is configured, the installation location setting is stored in the air conditioner even if the power
supply is turned off. To change the installation location setting, set a location again with the remote control.
• During the operation, an installation location cannot be set.
• When the air conditioner is installed at the location within 50 cm from the wall, it is recommended to change the location to “Right
End Installation” or “Left End Installation”.
NOTE
RKW012A412D_EN_001-032 4/15/14, 13:5625