Minimum 3 minutes 1
ON
Thermostat
Indoor fan
Auto vane
Booster heater
Compressor
ON
LOW or HIGH
Initally 10 degrees
(Changeable by remote controller setting)
LOW or HIGH
ON
ON
OFF
OFF
CLOSE CLOSE
OFF
OFF
OFF
Operation starts by
POWER button
ON.
Operation stops by
POWER button
OFF.
The room temperature
displayed on Remote
controller becomes equal
to set temperature.
The room temperature
displayed on Remote
controller rises above
set temperature.
W
<COOL operation time chart>
w1 Even if the room temperature displayed on remote controller rises above the set temperature during this period, the compressor will not start until this period
has ended.
2. INDOOR UNIT CONTROL
2-1 COOL operation
<How to operate>
1 Press POWER ON/OFF button.
2 Press COOL / DRY button to set operation mode to Cool.
NOTE : "Cool" and "DRY" are alternately displayed each time
COOL / DRY button is pressed.
3 To set desired temperature, press WARMER or COOLER
button.
NOTE : Set temperature changes by 2˚F in the range 66~86˚F,
each time WARMER or COOLER button is pressed.
MITSUBISHI ELECTRIC
-CENTRALLY CONTROLLED-
STAND BY
DEFROST
ON
CHECK DRY
COOL
HEAT
CHECK
SET TEMP
TIMER OFF
AUTO STOP
AUTO START
F
HR
F
LOW HIGH
AUTO RETURN
CHECK TEST RUN
POWER
ON/OFF
HEAT
SET
TEMPERATURE
AUTO COOL/DRY
COOLERWARMER
TIMER MODE HOURS
FAN SPEED LOW/HIOGH
AIR
DISCHARGE
UP/DOWN
SWING
STOP
CHECK TEST RUN
OC120--1.qxp 24/6/97 12:22 AM Page 31