8 MICROPROCESSOR CONTROL
Compressor and
outdoor fan : ON-
OFF
Operation mode
change :COOL-
HEAT.
1.OUTLINE OF MICROPROCESSOR CONTROL
OFF-ON switching.
COOL/DRY-AUTO-HEAT selector switching.
Thermostat setting.
TIMER mode selector-switching and Timer
setting.
HIGH-LOW fan speed switching.
AUTO Vane selector (AIR DISCHARGE)
switching.
TEST RUN switching.
CHECK mode switching.
(Self diagnostic trouble shooting)
Room temperature thermistor (RT1)
Indoor coil thermistor (RT2)
Autovane’s angle setting.
Booster heater ON-OFF Control.
Emergency stop.
Compressor protection-
device working
Defrosting
START-STOP
Fan speed control.
Crankcase heater control
ON-OFF.
Self diagnostic function
Independent Control of
Outdoor Unit
OUTPUT to indoor unit
INPUT from indoor unit
INPUT to remote controller
Remote controller board
Processes and transmits
orders.orders.
OUTPUT to remote controller
Indoor controller board
Receives orders from remote controller and tem-
perature data from indoor unit.
Processes orders and data.
Controls indoor and outdoor operation.
Self diagnostic function.
w System control operation.
w Emergency operation.
w Set by dipswitch on indoor controller board.
Transmits the power to remote controller.
OUTPUT to outdoor unit
12VDC
Non-polar, two-wire cable
maxinmum length 500 meters
Signal
Remote controller
LCD indicator
Polar three-wire cable
12VDC
1 2 3
1
2
3
Indoor
unit
Outdoor unit
MITSUBISHI ELECTRIC
-CENTRALLY CONTROLLED-
STAND BY
DEFROST
ON
CHECK DRY
COOL
HEAT
CHECK
SET TEMP
TIMER OFF
AUTO STOP
AUTO START
F
HR
F
LOW HIGH
AUTO RETURN
CHECK TEST RUN
POWER
ON/OFF
HEAT
SET
TEMPERATURE
AUTO COOL/DRY
COOLERWARMER
TIMER MODE HOURS
FAN SPEED LOW/HIOGH
AIR
DISCHARGE
UP/DOWN
SWING
STOP
CHECK TEST RUN
OC120--1.qxp 24/6/97 12:22 AM Page 30