Mitsubishi Electronics PUGH36AYB Heat Pump User Manual


 
036-21544-001 Rev. B (1103)
14 Mitsubishi Electronics 2003
PKH36FK+PUGH36 (Indoor Air = 885 CFM)
75 °F Outdoor Air Temperature
Indoor Wet
Bulb (°F)
Cooling
Capacity
(Btu/hr)
EER
Total
Power
(Watts)
Net Sensible Cooling Capacity (Btu/hr)
Pressures
(psig)
Indoor Dry Bulb (°F)
70 75 80 85 90 Suction Discharge
63 31,375 10.90 2,878 25,577 28,969 25,106 21,243 24,635 68 215
65 31,927 11.03 2,895 21,650 25,042 23,179 21,316 24,708 69 216
67 32,479 11.16 2,912 17,722 21,114 21,251 21,389 24,781 70 218
69 33,031 11.28 2,928 13,795 17,187 19,324 21,461 24,853 70 219
71 33,583 11.41 2,943 9,867 13,259 17,397 21,534 24,926 71 220
85 °F Outdoor Air Temperature
Indoor Wet
Bulb (°F)
Cooling
Capacity
(Btu/hr)
EER
Total
Power
(Watts)
Net Sensible Cooling Capacity (Btu/hr)
Pressures
(psig)
Indoor Dry Bulb (°F)
70 75 80 85 90 Suction Discharge
63 29,459 9.78 3,013 20,869 24,261 26,781 29,301 32,693 71 244
65 30,374 10.13 2,997 18,093 21,485 24,031 27,325 30,717 71 242
67 31,040 10.49 2,958 15,316 18,708 21,282 25,350 28,742 72 241
69 32,079 10.48 3,060 12,540 15,932 19,279 23,374 26,766 74 247
71 33,119 10.47 3,164 9,763 13,155 17,277 21,399 24,791 77 253
95 °F Outdoor Air Temperature
Indoor Wet
Bulb (°F)
Cooling
Capacity
(Btu/hr)
EER
Total
Power
(Watts)
Net Sensible Cooling Capacity (Btu/hr)
Pressures
(psig)
Indoor Dry Bulb (°F)
70 75 80 85 90 Suction Discharge
63 27,543 8.75 3,148 16,161 19,553 28,456 37,358 40,750 73 272
65 28,821 9.30 3,099 14,536 17,928 24,884 33,335 36,727 73 269
67 29,600 9.85 3,005 12,910 16,302 21,312 29,311 32,703 74 265
69 31,128 9.75 3,193 11,285 14,677 19,235 25,288 28,680 78 275
71 32,655 9.65 3,384 9,659 13,051 17,158 21,264 24,656 82 285
105 °F Outdoor Air Temperature
Indoor Wet
Bulb (°F)
Cooling
Capacity
(Btu/hr)
EER
Total
Power
(Watts)
Net Sensible Cooling Capacity (Btu/hr)
Pressures
(psig)
Indoor Dry Bulb (°F)
70 75 80 85 90 Suction Discharge
63 25,204 7.69 3,278 15,258 18,650 23,642 28,634 32,026 76 306
65 26,584 8.05 3,300 13,654 17,046 21,720 27,141 30,533 78 306
67 27,715 8.40 3,297 12,050 15,442 19,799 25,649 29,041 79 307
69 29,220 8.51 3,432 10,447 13,839 18,624 24,157 27,549 83 314
71 30,725 8.61 3,567 8,843 12,235 17,450 22,665 26,057 86 321
115 °F Outdoor Air Temperature
Indoor Wet
Bulb (°F)
Cooling
Capacity
(Btu/hr)
EER
Total
Power
(Watts)
Net Sensible Cooling Capacity (Btu/hr)
Pressures
(psig)
Indoor Dry Bulb (°F)
70 75 80 85 90 Suction Discharge
63 22,865 6.71 3,408 14,354 17,746 18,828 19,909 23,301 79 339
65 24,347 6.95 3,502 12,772 16,164 18,556 20,948 24,340 82 344
67 25,830 7.20 3,590 11,191 14,583 18,285 21,988 25,380 85 348
69 27,312 7.44 3,672 9,609 13,001 18,014 23,027 26,419 87 353
71 28,794 7.68 3,749 8,027 11,419 17,743 24,066 27,458 90 357
PERFORMANCE DATA - OPERATING PRESSURES - COOLING
4