Mitsubishi Electronics PL24FK21 Air Conditioner User Manual


 
OC194-10
NOTES : A point on the curve shows the reference point.
PL24FK21 COOLING CAPACITY PL30FK21 COOLING CAPACITY
Total power consumption (kW) Total capacity (x10
3
Btu/h)
Outdoor intake air DB temperature ( F)
36
30
42
24
4.0
3.5
3.0
2.5
63
67
71
63
67
71
SHF=0.76
23
32 35
45 55
65
(67)
75 85 95 105 115
Indoor intake air WB temperature ( F)
Indoor intake air WB temperature ( F)
Total power consumption (kW) Total capacity (x10
3
Btu/h)
Outdoor intake air DB temperature ( F)
30
24
36
18
3.0
2.5
2.0
1.5
63
67
71
63
67
71
SHF=0.71
23
32 35
45 55
65
(67)
75 85 95 105 115
Indoor intake air WB temperature ( F)
Indoor intake air WB temperature ( F)
3.5
PL36FK31 COOLING CAPACITY PL42FK21 COOLING CAPACITY
Total power consumption (kW) Total capacity (x10
3
Btu/h)
Outdoor intake air DB temperature ( F)
48
42
54
36
2.0
1.5
63
67
71
63
67
71
SHF=0.72
23
32 35
45 55
65
(67)
75 85 95 105 115
Indoor intake air WB temperature ( F)
Indoor intake air WB temperature ( F)
Total power consumption (kW) Total capacity (x10
3
Btu/h)
Outdoor intake air DB temperature ( F)
42
36
48
30
4.0
3.5
3.0
2.5
63
67
71
63
67
71
SHF=0.73
23
32 35
45 55
65
(67)
75 85 95 105 115
Indoor intake air WB temperature ( F)
Indoor intake air WB temperature ( F)
4.5