- 8 -
SPECIFICATIONS
Model name
Service
reference
Power supply Indoor
Outdoor
%
Capacity step
Refrigerant
Refrigerant charge
kg
Capillary tube
Refrigerant control
Indoor Unit
Model name
Service
reference
External finish
Acrylic resin coating (Munsell 5Y 8/1)
Dimension Width mm
Depth
mm
Height
Width
Depth
Height
mm
Net weight
Compressor
kg
Indoor coil
Cross fin coil
Indoor fan
Centrifugal (plastic) - Belt driveCentrifugal (plastic) - Direct drive
Indoor fan motor
Three phase induction motor
Single phase induction motor
kW
Motor output
Indoor fan air flow
CMM
CFM
L/S
External static
pressure
mmAq
Pa
Sound pressure level
dB(A)
Outdoor unit
Model name
Service
reference
External finish
Dimension
mm
mm
mm
Net weight
kg
Outdoor coil
Cross fin coil
Outdoor fan
Propeller-Direct drive
Outdoor fan motor
Three phase induction motor
No. Motor output
kW
No. Motor output kW
Outdoor fan air flow CMM
CFM
L/S
Sound pressure level dB(A)
Protection devices
3N~ 380~415V 50Hz
3N~ 380~415V 50Hz
~ 220~240V 50Hz
3N~
380~415V 50Hz
0-100 0-50-100
5.7 5.0 8.7 2
4.8 2 9.7
2 0.09 2 0.15 1 0.24 2 0.24
Note1.Cooling capacity and sound pressure level are based on the following conditions.
Indoor;27˚CDB,19˚CWB, Outdoor;35˚CDB
Cooling capacity is based 5m pipe length.
2.Refergirant charge volumes are factory charged (at 5m piping length).Refrigerant is enclosed with the outdoor unit.
3.Gross capacity do not include a deduction for evaporator fan motor heat.
4.The measuring point of the Sound pressure level is 1m from the unit front surface.
5.Specification subject to change without notice.
R-22
Drain connection
mm
Hermetic line start(reciprocating)
PE-7MYC PE-8MYC PE-10MYC
PE-15MYC PE-20MYC
PE-7MYC-EU PE-8MYC-EU
PE-10MYC-EU
PE-15MYC1-EU PE-20MYC-EU
PE-7MYC PE-8MYC PE-10MYC
PE-15MYC PE-20MYC
PE-7MYC-EU PE-8MYC-EU
PE-10MYC-EU
PE-15MYC1-EU PE-20MYC-EU
Total cooling capacity
(Gross)
Total cooling capacity
(Net)
kW
Btu/h
kcal/h
17.9
61,100
15,400
kW
Btu/h
kcal/h
17.2/17.1
58,700/58,300
14,800/14,700
22.0 28.8
75,100 98,300
18,900 24,800
21.4 27.8
73,000 94,900
18,400 23,900
47.0 57.6
160,400 196,600
40,400 49,500
45.5/45.3 56.1/55.2
155,200/154,600 191,400/188,300
39,100/39,000 48,200/47,500
Sensible cooling capacity
(Gross)
kW
Btu/h
kcal/h
14.3
48,800
12,300
17.6 23.0
60,100 78,500
15,100 19,800
37.6 46.1
128,300 157,300
32,300 39,600
Galvanized steel
428
1,415 1,615
650
67 70 84
706
1,690 1,993
865
180 212
60
2,119
1,000
70
2,472
1,167
90
3,179
1,500
140
4,945
2,333
180
6,358
3,000
0.21
0.7 1.0
2.2
3.7
1 5.0 1 5.5 1 7.5 2 5.5 2 7.5
Crankcase heater W 62 62 72 2 62 2 72
PU-7MYC PU-8MYC PU-10MYC PU-15MYC PU-20MYC
PU-7MYC1-EU(S) PU-8MYC1-EU(S) PU-10MYC1-EU(S) PU-15MYC1-EU(S) PU-20MYC1-EU(S)
980
1,400
700
202
205
230
1,230
998
961
1,996
998
285
360
190 220
6,711 7,770
3,167
210
7,415
3,000 3,667
65 65 65 67 68
240
8,477
4,000
480
16,954
8,000
High pressure switch, freeze & frost protection, Fuse
Internal thermostat (comp & indoor fan, outdoor fan)
Over current relay (comp & indoor fan, outdoor fan)
6.2/12.5
62/125
10/20
100/200
55
50/125
5/12.5
56 59
25.4
61 62
PE-7~20MYC