8
5
SPECIFICATION
Outdoor model
Indoor units number
Indoor units total capacity (Connectable)
indoor units total capacity (Simultaneous operation)
Piping total length
Connecting pipe length
Height difference (Indoor ~ Outdoor)
Height difference (Indoor ~ Indoor)
Function
Capacity
Dehumidification
Outdoor air flow
Power outlet
Running current
Power input
Auxiliary heater
Crankcase heater
Power factor
Starting current
Compressor motor current
Fan motor current
Model
Output
Winding
resistance(at20:)
Model
Winding
resistance(at20:)
Dimensions WOHOD
Weight
Sound level (Hi)
Fan speed (Hi)
Fan speed regulator
Refrigerant filling
capacity(R-22)
Refrigerating oil (Model)
Thermistor RT61
Thermistor RT62
Thermistor RT63
Thermistor RT65
Thermistor RT66,67
Thermistor RT68,69
kW
R/h
K /h
A
A
W
A(kW)
W
%
A
A
A
W
"
"
mm
kg
dB
rpm
kg
cc
k"
k"
k"
k"
k"
k"
Compressor
Electrical
data
Fan
motor
Special
remarks
Capacity System
Coefficient of performance(C.O.P)
Outdoor unit power supply
MXZ-32SV -
E1
,
MXZ-32SV -
E2
Single phase
220-240V,50Hz
2 to 4
Total model name 42
Total model name 42
Max. 60
Max. 25
10
10
2400-2640
25
—
—
90.0
15.05-13.80
0.6
THV-247FBA (ROTARY)
2100
U-V 0.61
V-W 0.61 W-U 0.61
RA6V60-BA
WHT-BLK 78.7 BLK-YLW 26.9
YLW-BLU 11.7 BLU-RED 83.6
900o900o320 (+35)
79
630-675
3
3.9
870 (MS-56)
13.4 (at 100:)
10.0 (at 25:)
17.0 (at 50:)
10.0 (at 25:)
10.0 (at 25:)
10.0 (at 25:)
Cooling
8.0 (0.9~9.0)
—
15.05-13.80
2980(260~4270)
15.71-14.35
2.68
45-47
Heating
9.3 (0.9~11.6)
—
14.04-12.87
2780(270~3500)
13.44-12.27
3.35
46-48
TEST CONDITIONS COOLING INDOOR DB27.0°C WB19.0°C
OUTDOOR DB35.0°C WB24.0°C
HEATING INDOOR DB20.0°C
OUTDOOR DB 7.0°C WB 6.0°C
✽1 Electrical data is for only outdoor unit.
OB254-1.qxp 03.1.16 4:33 PM Page 8