9
Outdoor model
MUZ-GE60VA
MUZ-GE60VAD
MUZ-GE71VA
MUZ-GE71VAD
MUZ-GE80VA MUZ-GE80VA2
MUZ-GE80VAD
Power supply
Single phase, 230 V, 50 Hz
Capacity
Rated frequency (Min.-Max.)
Cooling
kW
6.0 (1.5 - 7.5) 7.1 (2.4- 8.7)
8.0 (2.4 - 9.2)
7.8 (2.4 - 9.2)
Heating
6.8 (2.0 - 9.3) 8.1 (2.2 - 9.9) 9.0 (2.2 - 11.1)
Breaker Capacity
A20
Electrical data
Power input 1 (Total)
Cooling
W
1,760 2,130 2,560 2,460
Heating
1,770 2,110 2,540 2,550
Running current 1
(Total)
Cooling
A
7.8 9.4 11.3 10.8
Heating
7.8 9.5 11.2
Power factor 1 (Total)
Cooling
%
98 99 98 99
Heating
98 97 99
Starting current 1 (Total)
A 7.8 9.5 11.3 11.2
Coef cient of performance
(COP) 1 (Total)
Cooling
3.40 3.41 3.33 3.12 3.17
Heating
3.84 3.83 3.84 3.54 3.53
Compressor
Model
SNB130FGBMT SNB172FEKMT
Output
W 900 1,200
Current 1
Cooling
A
6.62 6.44 8.02 8.06 9.89 9.39 9.43
Heating
6.37 6.34 8.13 8.17 9.83 9.87
Refrigeration oil
(Model)
L 0.35 (FV50S) 0.4 (FV50S)
Fan motor
Model
RC0J60-BC
Current 1
Cooling
A
0.84 0.93 0.83 0.86
Heating
0.93 0.82
Dimensions W × H × D
mm 840 × 880 × 330
Weight
kg 50 53
Special remarks
Dehumidi cation Cooling
L/h 1.9 2.2 2.9 2.7
Air ow 1
Cooling
High
m
3
/h
3,492 3,426
Med.
3,066 3,006
Low
1,692 1,512
Heating
High
2,952 2,892
Med.
2,952 2,892
Low
2,226 2,280
Sound level 1
Cooling
dB(A)
55
Heating
55
Fan speed
Cooling
High
rpm
950
Med.
840
Low
480 450
Heating
High
810
Med.
810
Low
620 650
Fan speed regulator
3
Refrigerant lling capacity
(R410A)
kg 1.55 1.90
NOTE: Test conditions are based on AS/NZS 3823.1.1.
Cooling: Indoor Dry-bulb temperature 27°C Wet-bulb temperature 19°C
Outdoor Dry-bulb temperature 35°C Wet-bulb temperature (24°C)
Heating: Indoor Dry-bulb temperature 20°C Wet-bulb temperature 15.5°C
Outdoor Dry-bulb temperature 7°C Wet-bulb temperature 6°C
Refrigerant piping length (one way): 5 m
1 Measured under rated operating frequency.
OBH532E