Mitsubishi Electronics MUY-GE15NA Air Conditioner User Manual


 
12
MUZ-GE18NA MUY-GE18NA
Outdoor
heat
exchanger
Flared connection
Defrost
thermistor
RT61
(MUZ)
Discharge
temperature
thermistor
RT62
Flared connection
Stop valve
(with strainar)
Stop valve
(with service port)
Capillary tube
O.D. 0.142 × I.D. 0.094
× 1-31/32
(
ø
3.6
×
ø
2.4
×
50
)
Refrigerant flow in cooling
Compressor
4-way valve
Refrigerant flow in heating
(MUZ)
Refrigerant pipe
ø
1/2
(with heat insulator)
Refrigerant pipe
ø
1/4
(with heat insulator)
LEV
R.V. coil
(MUZ)
heating ON
cooling OFF
Muffler
#100
Receiver
Outdoor heat
exchanger
temperature
thermistor
RT68
Ambient
temperature
thermistor
RT65
Strainer
#100
Service port
Service port
Unit: inch
Max. Length
A
Max. Height
difference
B
Indoor
unit
Outdoor unit
MAX. REFRIGERANT PIPING LENGTH and MAX. HEIGHT DIFFERENCE
Model
Refrigerant piping: ft. Piping size O.D: in.
Max. Length
A
Max. Height difference
B
Gas Liquid
MUZ-GE09/12/15NA
MUY-GE09/12/15NA
65 40
3/8 (GE09/12)
1/2 (GE15)
1/4
MUZ-GE18NA
MUY-GE18NA
100 50 1/2